authorMario Scheithauer <mario.scheithauer@siemens.com>2023-09-01 07:54:20 +0200
committerMartin L Roth <gaumless@gmail.com>2023-09-02 16:25:30 +0000
commita52d38b637d08334cd5cf4e11750f2cf9d3dd849 (patch)
treee354a16030fc0cdfcd54d6543b74cd3f1589e2e9 /src/mainboard
parentfd6908a748ad00aa6557e08309b9aad9abcdceb2 (diff)
mb/siemens/mc_apl2: Set Full Reset Bit into Reset Control Register
With the introduction of a new Linux version a problem has appeared after a software initiated reset via CF9h register. The problem manifests itself in the fact that the Linux kernel does not start after the reboot. The problem is solved by setting bit 3 to 1 in Reset Control Register (I/O port CF9h). This leads to the fact that the PCH will drive SLP_S3 active low in the reset sequence. It leads to the same behavior as in commit 04ea73ee78bc ("siemens/mc_apl3: Set Full Reset Bit into Reset Control Register") explained. Change-Id: Ibc6d538c939e38732f42995d5ec6c8b61f979a6a Signed-off-by: Mario Scheithauer <mario.scheithauer@siemens.com> Reviewed-on: https://review.coreboot.org/c/coreboot/+/77603 Reviewed-by: Werner Zeh <werner.zeh@siemens.com> Reviewed-by: Jan Samek <jan.samek@siemens.com> Tested-by: build bot (Jenkins) <no-reply@coreboot.org>
Diffstat (limited to 'src/mainboard')
-rw-r--r--src/mainboard/siemens/mc_apl1/variants/mc_apl2/mainboard.c6
1 files changed, 6 insertions, 0 deletions
diff --git a/src/mainboard/siemens/mc_apl1/variants/mc_apl2/mainboard.c b/src/mainboard/siemens/mc_apl1/variants/mc_apl2/mainboard.c
index 430e67e171..af9e25dc06 100644
--- a/src/mainboard/siemens/mc_apl1/variants/mc_apl2/mainboard.c
+++ b/src/mainboard/siemens/mc_apl1/variants/mc_apl2/mainboard.c
@@ -1,5 +1,6 @@
/* SPDX-License-Identifier: GPL-2.0-only */
+#include <cf9_reset.h>
#include <device/pci_def.h>
#include <device/pci_ids.h>
#include <device/pci_ops.h>
@@ -17,4 +18,9 @@ void variant_mainboard_final(void)
pci_or_config16(dev, PCI_COMMAND, PCI_COMMAND_MASTER);
}
}
+
+ /* Set Full Reset Bit in Reset Control Register (I/O port CF9h). When Bit 3 is set to 1
+ and then a warm reset is triggered the PCH will drive SLP_S3 active (low). SLP_S3 is
+ then used on the mainboard to generate the right reset timing. */
+ outb(FULL_RST, RST_CNT);
}