#!/usr/bin/env python3
import paho.mqtt.client as mqtt
import re
from home.mqtt import MqttBase
from home.mqtt.payload.inverter import Status, Generation
from home.database import InverterDatabase
from home.config import config
class MqttReceiver(MqttBase):
def __init__(self):
super().__init__(clean_session=False)
self.database = InverterDatabase()
def on_connect(self, client: mqtt.Client, userdata, flags, rc):
super().on_connect(client, userdata, flags, rc)
self._logger.info("subscribing to hk/#")
client.subscribe('hk/#', qos=1)
def on_message(self, client: mqtt.Client, userdata, msg):
super().on_message(client, userdata, msg)
try:
match = re.match(r'(?:home|hk)/(\d+)/(status|gen)', msg.topic)
if not match:
return
# FIXME string home_id must be supported
home_id, what = int(match.group(1)), match.group(2)
if what == 'gen':
gen = Generation.unpack(msg.payload)
self.database.add_generation(home_id, gen.time, gen.wh)
elif what == 'status':
s = Status.unpack(msg.payload)
self.database.add_status(home_id,
client_time=s.time,
grid_voltage=int(s.grid_voltage*10),
grid_freq=int(s.grid_freq * 10),
ac_output_voltage=int(s.ac_output_voltage * 10),
ac_output_freq=int(s.ac_output_freq * 10),
ac_output_apparent_power=s.ac_output_apparent_power,
ac_output_active_power=s.ac_output_active_power,
output_load_percent=s.output_load_percent,
battery_voltage=int(s.battery_voltage * 10),
battery_voltage_scc=int(s.battery_voltage_scc * 10),
battery_voltage_scc2=int(s.battery_voltage_scc2 * 10),
battery_discharge_current=s.battery_discharge_current,
battery_charge_current=s.battery_charge_current,
battery_capacity=s.battery_capacity,
inverter_heat_sink_temp=s.inverter_heat_sink_temp,
mppt1_charger_temp=s.mppt1_charger_temp,
mppt2_charger_temp=s.mppt2_charger_temp,
pv1_input_power=s.pv1_input_power,
pv2_input_power=s.pv2_input_power,
pv1_input_voltage=int(s.pv1_input_voltage * 10),
pv2_input_voltage=int(s.pv2_input_voltage * 10),
mppt1_charger_status=s.mppt1_charger_status,
mppt2_charger_status=s.mppt2_charger_status,
battery_power_direction=s.battery_power_direction,
dc_ac_power_direction=s.dc_ac_power_direction,
line_power_direction=s.line_power_direction,
load_connected=s.load_connected)
except Exception as e:
self._logger.exception(str(e))
if __name__ == '__main__':
config.load('inverter_mqtt_receiver')
server = MqttReceiver()
server.connect_and_loop()
|