summaryrefslogtreecommitdiff
path: root/src/home/database/inverter.py
diff options
context:
space:
mode:
Diffstat (limited to 'src/home/database/inverter.py')
-rw-r--r--src/home/database/inverter.py102
1 files changed, 102 insertions, 0 deletions
diff --git a/src/home/database/inverter.py b/src/home/database/inverter.py
new file mode 100644
index 0000000..8902f04
--- /dev/null
+++ b/src/home/database/inverter.py
@@ -0,0 +1,102 @@
+from .clickhouse import get_clickhouse
+from time import time
+
+
+class InverterDatabase:
+ def __init__(self):
+ self.db = get_clickhouse('solarmon')
+
+ def add_generation(self, home_id: int, client_time: int, watts: int) -> None:
+ self.db.execute(
+ 'INSERT INTO generation (ClientTime, ReceivedTime, HomeID, Watts) VALUES',
+ [[client_time, round(time()), home_id, watts]]
+ )
+
+ def add_status(self, home_id: int,
+ client_time: int,
+ grid_voltage: int,
+ grid_freq: int,
+ ac_output_voltage: int,
+ ac_output_freq: int,
+ ac_output_apparent_power: int,
+ ac_output_active_power: int,
+ output_load_percent: int,
+ battery_voltage: int,
+ battery_voltage_scc: int,
+ battery_voltage_scc2: int,
+ battery_discharging_current: int,
+ battery_charging_current: int,
+ battery_capacity: int,
+ inverter_heat_sink_temp: int,
+ mppt1_charger_temp: int,
+ mppt2_charger_temp: int,
+ pv1_input_power: int,
+ pv2_input_power: int,
+ pv1_input_voltage: int,
+ pv2_input_voltage: int,
+ mppt1_charger_status: int,
+ mppt2_charger_status: int,
+ battery_power_direction: int,
+ dc_ac_power_direction: int,
+ line_power_direction: int,
+ load_connected: int) -> None:
+ self.db.execute("""INSERT INTO status (
+ ClientTime,
+ ReceivedTime,
+ HomeID,
+ GridVoltage,
+ GridFrequency,
+ ACOutputVoltage,
+ ACOutputFrequency,
+ ACOutputApparentPower,
+ ACOutputActivePower,
+ OutputLoadPercent,
+ BatteryVoltage,
+ BatteryVoltageSCC,
+ BatteryVoltageSCC2,
+ BatteryDischargingCurrent,
+ BatteryChargingCurrent,
+ BatteryCapacity,
+ HeatSinkTemp,
+ MPPT1ChargerTemp,
+ MPPT2ChargerTemp,
+ PV1InputPower,
+ PV2InputPower,
+ PV1InputVoltage,
+ PV2InputVoltage,
+ MPPT1ChargerStatus,
+ MPPT2ChargerStatus,
+ BatteryPowerDirection,
+ DCACPowerDirection,
+ LinePowerDirection,
+ LoadConnected) VALUES""", [[
+ client_time,
+ round(time()),
+ home_id,
+ grid_voltage,
+ grid_freq,
+ ac_output_voltage,
+ ac_output_freq,
+ ac_output_apparent_power,
+ ac_output_active_power,
+ output_load_percent,
+ battery_voltage,
+ battery_voltage_scc,
+ battery_voltage_scc2,
+ battery_discharging_current,
+ battery_charging_current,
+ battery_capacity,
+ inverter_heat_sink_temp,
+ mppt1_charger_temp,
+ mppt2_charger_temp,
+ pv1_input_power,
+ pv2_input_power,
+ pv1_input_voltage,
+ pv2_input_voltage,
+ mppt1_charger_status,
+ mppt2_charger_status,
+ battery_power_direction,
+ dc_ac_power_direction,
+ line_power_direction,
+ load_connected
+ ]])