summaryrefslogtreecommitdiff
path: root/src/mainboard/roda/rk9/acpi/ec.asl
blob: 7284ccd1623a0b2f8662ca722ca908b46c410300 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
/* SPDX-License-Identifier: GPL-2.0-only */

Device(EC0)
{
	Name (_HID, EISAID("PNP0C09"))
	Name (_UID, 1)

	Name (_GPE, 23)	// GPI07 / GPE23 -> Runtime SCI
	Name (ECON, 0)
	Name (QEVT, 0)

	OperationRegion(ERAM, EmbeddedControl, 0x00, 0xff)
	Field (ERAM, ByteAcc, NoLock, Preserve)
	{
			Offset(0xb1),
		CPWR,   1,
		ACCH,   1, // AC connected (charger present)
		B1PR,   1, // battery 1 present
		B2PR,   1, // battery 2 present
		B1CH,   1, // battery 1 charged
		B2CH,   1, // battery 2 charged
			Offset(0xb2),
		B1CG,   1, // battery 1 charging
		B2CG,   1, // battery 2 charging
		B1LO,   1, // battery 1 low
		B2LO,   1, // battery 2 low
			Offset(0xb3),
		B1DW,  16, // battery 1 design capacity
		B1FW,  16, // battery 1 last full charge capacity
		B1DV,  16, // battery 1 design voltage
		B1PW,  16, // battery 1 present capacity
			Offset(0xbd),
		B1PV,  16, // battery 1 present voltage
			Offset(0xc1),
		B2DW,  16, // battery 2 design capacity
		B2FW,  16, // battery 2 last full charge capacity
		B2DV,  16, // battery 2 design voltage
		B2PW,  16, // battery 2 present capacity
			Offset(0xcb),
		B2PV,  16, // battery 2 present voltage
			Offset(0xcf),
		FDDI,   1, // floppy on lpt indicator?
		LIDC,   1, // LID switch
			Offset(0xd0),
		TCPU,   8, // T_CPU in deg Celcius
			Offset(0xd6),
		/* exact purpose of these three is guessed,
		   but it's something about cooling */
		ALRL,   1, // active cooling low limit
		ALRH,   1, // active cooling high limit
		ALRC,   1, // active cooling clear
			Offset(0xe8),
		B1RW,  16, // battery 1 remaining capacity
		B2RW,  16, // battery 2 remaining capacity
	}

	Method (_CRS, 0)
	{
		Name (ECMD, ResourceTemplate()
		{
			IO (Decode16, 0x62, 0x62, 1, 1)
			IO (Decode16, 0x66, 0x66, 1, 1)
		})

		Return (ECMD)
	}

	Method (_REG, 2)
	{
		// This method is needed by Windows XP/2000 for
		// EC initialization before a driver is loaded

		If (LEqual(Arg0, 0x03)) {
			Store (Arg1, ECON)
		}
	}

	// EC Query methods

	Method (_Q11, 0)
	{
		Store("_Q11: Fn-F8 (Sleep Button) pressed", Debug)
		Notify(SLPB, 0x80)
	}

	Method (_Q30, 0)
	{
		Store("_Q30: AC In", Debug)
		Notify(ADP1, 0x80)	// Tell the Power Adapter
		PNOT()			// and the CPU and Battery
	}

	Method (_Q31, 0)
	{
		Store("_Q31: AC Out", Debug)
		Notify(ADP1, 0x80)	// Tell the Power Adapter
		PNOT()			// and the CPU and Battery
	}

	Method (_Q32, 0)
	{
		Store("_Q32: Bat1 In", Debug)
		Notify(BAT1, 0x81)
	}

	Method (_Q33, 0)
	{
		Store("_Q33: Bat1 Out", Debug)
		Notify(BAT1, 0x81)
	}

	Method (_Q34, 0)
	{
		Store("_Q34: Bat2 In", Debug)
		Notify(BAT2, 0x81)
	}

	Method (_Q35, 0)
	{
		Store("_Q35: Bat2 Out", Debug)
		Notify(BAT2, 0x81)
	}

	Method (_Q36, 0)
	{
		Store("_Q36: Bat1 Low Power", Debug)
		Notify(BAT1, 0x80)
	}

	Method (_Q37, 0)
	{
		Store("_Q37: Bat1 Full Charge", Debug)
		Notify(BAT1, 0x80)
	}

	Method (_Q38, 0)
	{
		Store("_Q38: Bat2 Low Power", Debug)
		Notify(BAT2, 0x80)
	}

	Method (_Q39, 0)
	{
		Store("_Q39: Bat2 Full Charge", Debug)
		Notify(BAT2, 0x80)
	}

	Method (_Q40, 0)
	{
		Store("_Q40: LID Open/Close", Debug)
		Notify(LID0, 0x80)
	}

	Method (_Q41, 0)
	{
		Store("_Q41: Floppy on Parallel Port: Call the Museum!", Debug)
	}

	Method (_Q50, 0)
	{
		Store("_Q50: Processor is hot", Debug)
		Notify(\_TZ.THRM, 0x80)
	}

	Method (_Q51, 0)
	{
		Store("_Q51: Processor is boiling", Debug)
		Notify(\_TZ.THRM, 0x80)
	}

	Method (_Q52, 0)
	{
		Store("_Q52: Processor is burning", Debug)
		Notify(\_TZ.THRM, 0x80)
	}

}