if BOARD_LIPPERT_HURRICANE_LX
config BOARD_SPECIFIC_OPTIONS # dummy
def_bool y
select ARCH_X86
select CPU_AMD_GEODE_LX
select NORTHBRIDGE_AMD_LX
select SOUTHBRIDGE_AMD_CS5536
select SUPERIO_ITE_IT8712F
select HAVE_PIRQ_TABLE
select PIRQ_ROUTE
select UDELAY_TSC
# Board is equipped with a 1 MB SPI flash, however, due to limitations
# of the IT8712F Super I/O, only the top 512 KB are directly mapped.
select BOARD_ROMSIZE_KB_512
select PLL_MANUAL_CONFIG
select CORE_GLIU_500_333
config MAINBOARD_DIR
string
default lippert/hurricane-lx
config MAINBOARD_PART_NUMBER
string
default "Hurricane-LX"
config IRQ_SLOT_COUNT
int
default 8
config BOARD_OLD_REVISION
bool "Board is old pre-3.0 revision"
default n
select POWER_BUTTON_DEFAULT_DISABLE
help
Look on the bottom side for a number like 406-0001-30. The last 2
digits state the PCB revision (3.0 in this example). For 2.0 or older
boards choose Y, for 3.0 and newer say N.
Old revision boards need a jumper shorting the power button to
power on automatically. You may enable the button only after this
jumper has been removed. New revision boards are not restricted
in this way, and always have the power button enabled.
config POWER_BUTTON_FORCE_ENABLE
def_bool y if !BOARD_OLD_REVISION
config ONBOARD_UARTS_RS485
bool "Switch on-board serial ports to RS485"
default n
help
If selected, both on-board serial ports will operate in RS485 mode
instead of RS232.
config PLLMSRlo
hex
default 0x00de6001
endif # BOARD_LIPPERT_HURRICANE_LX
|