1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
|
/* SPDX-License-Identifier: GPL-2.0-only */
/*
* The mainboard must define strings in the root scope to
* report device-specific battery information to the OS.
*
* BATM: Model
* BATS: Serial
* BATV: Vendor
*/
// Scope (EC0)
Device (BAT0)
{
Name (_HID, EISAID ("PNP0C0A"))
Name (_UID, 1)
Name (_PCL, Package () { \_SB })
Name (PBIF, Package () {
0x00000001, // Power Unit: mAh
0xFFFFFFFF, // Design Capacity
0xFFFFFFFF, // Last Full Charge Capacity
0x00000001, // Battery Technology: Rechargeable
0xFFFFFFFF, // Design Voltage
0x00000003, // Design Capacity of Warning
0xFFFFFFFF, // Design Capacity of Low
0x00000001, // Capacity Granularity 1
0x00000001, // Capacity Granularity 2
"", // Model Number
"", // Serial Number
"LION", // Battery Type
"" // OEM Information
})
Name (PBST, Package () {
0x00000000, // Battery State
0xFFFFFFFF, // Battery Present Rate
0xFFFFFFFF, // Battery Remaining Capacity
0xFFFFFFFF, // Battery Present Voltage
})
Name (BSTP, 0)
// Workaround for full battery status, enabled by default
Name (BFWK, 1)
// Method to enable full battery workaround
Method (BFWE)
{
BFWK = 1
}
// Method to disable full battery workaround
Method (BFWD)
{
BFWK = 0
}
// Swap bytes in a word
Method (SWAB, 1, NotSerialized)
{
Local0 = Arg0 >> 8
Local1 = Arg0 << 8
Local1 &= 0xFF00
Local0 |= Local1
If (Local0 == 0xFFFF) {
Local0 = 0xFFFFFFFF
}
Return (Local0)
}
Method (_STA, 0, Serialized)
{
If (BTEX) {
Return (0x1F)
} Else {
Return (0x0F)
}
}
Method (_BIF, 0, Serialized)
{
// Update fields from EC
PBIF[1] = SWAB (BTDA)
PBIF[2] = SWAB (BTDF)
PBIF[4] = SWAB (BTDV)
PBIF[6] = SWAB (BTDL)
// Get battery info from mainboard
PBIF[9] = \BATM
PBIF[10] = \BATS
PBIF[12] = \BATV
Return (PBIF)
}
Method (_BST, 0, Serialized)
{
//
// 0: BATTERY STATE
//
// bit 0 = discharging
// bit 1 = charging
// bit 2 = critical level
//
// Get battery state from EC
Local0 = BTST
Local1 = 0
// Check if AC is present
If (ACEX) {
// Set only charging/discharging bits
Local1 = Local0 & 3
} Else {
// Always discharging when on battery power
Local1 = 0x01
}
// Flag if the battery level is critical
Local4 = Local0 & 4
Local1 |= Local4
PBST[0] = Local1
// Notify if battery state has changed since last time
If (Local1 != BSTP) {
BSTP = Local1
Notify (BAT0, 0x80)
}
//
// 1: BATTERY PRESENT RATE
//
Local1 = SWAB (BTPR)
If (Local1 != 0xFFFFFFFF && Local1 >= 0x8000) {
Local1 ^= 0xFFFF
Local1++
}
PBST[1] = Local1
//
// 2: BATTERY REMAINING CAPACITY
//
Local1 = SWAB (BTRA)
If (Local1 != 0xFFFFFFFF && Local1 >= 0x8000) {
Local1 ^= 0xFFFF
Local1++
}
If (BFWK && ACEX && !Local0) {
// On AC power and battery is neither charging
// nor discharging. Linux expects a full battery
// to report same capacity as last full charge.
// https://bugzilla.kernel.org/show_bug.cgi?id=12632
Local2 = SWAB (BTDF)
// See if within ~3% of full
Local3 = Local2 >> 5
If (Local1 > Local2 - Local3 && Local1 < Local2 + Local3)
{
Local1 = Local2
}
}
PBST[2] = Local1
//
// 3: BATTERY PRESENT VOLTAGE
//
PBST[3] = SWAB (BTVO)
Return (PBST)
}
}
|