summaryrefslogtreecommitdiff
path: root/src/ec/compal/ene932/acpi/battery.asl
blob: c2adf617360b32bafc6fff98e4451972819f1736 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
/* SPDX-License-Identifier: GPL-2.0-only */

// Scope (EC0)

Device (BATX)
{
	Name (_HID, EISAID ("PNP0C0A"))
	Name (_UID, 1)
	Name (_PCL, Package () { \_SB })

	Name (PBIF, Package () {
		0x00000001,  // Power Unit: mAh
		0xFFFFFFFF,  // Design Capacity
		0xFFFFFFFF,  // Last Full Charge Capacity
		0x00000001,  // Battery Technology: Rechargeable
		0xFFFFFFFF,  // Design Voltage
		0x00000003,  // Design Capacity of Warning
		0xFFFFFFFF,  // Design Capacity of Low
		0x00000001,  // Capacity Granularity 1
		0x00000001,  // Capacity Granularity 2
		"",          // Model Number
		"",          // Serial Number
		"LION",      // Battery Type
		""           // OEM Information
	})

	Name (PBST, Package () {
		0x00000000,  // Battery State
		0xFFFFFFFF,  // Battery Present Rate
		0xFFFFFFFF,  // Battery Remaining Capacity
		0xFFFFFFFF,  // Battery Present Voltage
	})
	Name (BTNM, 0)  // Battery number

	// Workaround for full battery status, enabled by default
	Name (BFWK, 1)

	// Method to enable full battery workaround
	Method (BFWE)
	{
		BFWK = 1
	}

	// Method to disable full battery workaround
	Method (BFWD)
	{
		BFWK = 0
	}

	Method (_STA, 0, Serialized)
	{
		If (BOL0) {
			Return (0x1F)
		} Else {
			Return (0x0F)
		}
	}

	Method (_BIF, 0, Serialized)
	{
		// Update fields from EC
		PBIF [0] = BAM0
		PBIF [1] = BDC0
		PBIF [2] = BFC0
		PBIF [4] = BDV0
		Local1 = BFC0 / 100
		Local1 *= 10
		PBIF [5] = Local1
		Local1 = BFC0 / 100
		Local1 *= 3
		PBIF [6] = Local1

		PBIF [9] = ToString (Concatenate (BATD, 0x00))  // model
		PBIF [10] = ToHexString (BSN0)  // serial
		PBIF [12] = ToString (BMFN)  // vendor

		BTNM = BDN0	// Save the battery number

		Return (PBIF)
	}

	Method (_BST, 0, Serialized)
	{
		//
		// 0: BATTERY STATE
		//
		// bit 0 = discharging
		// bit 1 = charging
		// bit 2 = critical level
		//

		// Get battery state from EC and save it for the charging workaround
		Local0 = BST0
		PBST [0] = Local0

		//
		// 1: BATTERY PRESENT RATE/CURRENT
		//

		Local1 = BAC0
		Local1 = 0xFFFF - Local1
		PBST [1] = Local1

		//
		// 2: BATTERY REMAINING CAPACITY
		//
		Local1 = BFC0 * GAU0
		Local2 = Local1 % 100
		Local1 /= 100

		If (BFWK && ADPT && !Local0) {
			// On AC power and battery is neither charging
			// nor discharging.  Linux expects a full battery
			// to report same capacity as last full charge.
			// https://bugzilla.kernel.org/show_bug.cgi?id=12632
			Local2 = GAU0

			// See if within ~3% of full
			Local3 = Local2 >> 5
			If ((Local1 > (Local2 - Local3)) && (Local1 < (Local2 + Local3)))
			{
				Local1 = Local2
			}
		}
		PBST [2] = Local1

		//
		// 3: BATTERY PRESENT VOLTAGE
		//
		PBST [3] = BPV0

		// Check the Battery Number
		If(BDN0 != BTNM) {
			Notify(BATX, 0x81)
		}

		Return (PBST)
	}
}