## SPDX-License-Identifier: GPL-2.0-only

choice
	prompt "Timer driver"
	default TIMER_NONE if !ARCH_X86
	default TIMER_RDTSC if ARCH_X86

config TIMER_RDTSC
	bool "x86 rdtsc"
	depends on ARCH_X86

config TIMER_NONE
	bool "None"
	help
	  The timer driver is provided by the payload itself.

config TIMER_MCT
	bool "Exynos MCT"

config TIMER_TEGRA_1US
	bool "Tegra 1us"

config TIMER_IPQ806X
	bool "Timer for ipq806x platforms"

config TIMER_IPQ40XX
	bool "Timer for ipq40xx platforms"
	help
	  This is the timer driver for QCA IPQ40xx based
	  platforms.

config TIMER_ARM64_ARCH
	bool "Architecture Timer for ARM64 platforms"
	help
	  The cntfrq register needs to have been pre-initialized.

config TIMER_RK3288
	bool "Timer for Rockchip RK3288"

config TIMER_RK3399
	bool "Timer for Rockchip RK3399"

config TIMER_MTK
	bool "Timer for MediaTek"

endchoice

config TIMER_GENERIC_HZ
	int "Generic Timer Frequency"
	default 48000000 if TIMER_IPQ40XX
	default 6250000 if TIMER_IPQ806X
	default 24000000 if TIMER_MCT
	default 13000000 if TIMER_MTK
	default 24000000 if TIMER_RK3288
	default 24000000 if TIMER_RK3399
	default 1000000 if TIMER_TEGRA_1US
	default 0
	help
	  Clock frequency of generic time counter in Hertz. Leave at 0 to
	  disable when using a non-generic timer driver.

config TIMER_GENERIC_REG
	hex "Generic Timer Register Address"
	default 0x004A2000 if TIMER_IPQ40XX
	default 0x0200A028 if TIMER_IPQ806X
	default 0x101C0100 if TIMER_MCT
	default 0x10008068 if TIMER_MTK
	default 0xff810028 if TIMER_RK3288
	default 0xff850008 if TIMER_RK3399
	default 0x60005010 if TIMER_TEGRA_1US
	default 0x0
	help
	  Register address to read generic time counter from.

config TIMER_GENERIC_HIGH_REG
	hex "Generic Timer High Register Address"
	default 0x004A2004 if TIMER_IPQ40XX
	default 0x101C0104 if TIMER_MCT
	default 0x10008078 if TIMER_MTK
	default 0xff81002C if TIMER_RK3288
	default 0xff85000C if TIMER_RK3399
	default 0x0
	help
	  Register address to read high 32 bits of generic time counter from.