summaryrefslogtreecommitdiff
path: root/src/mainboard/asus/p5qc
diff options
context:
space:
mode:
authorArthur Heymans <arthur@aheymans.xyz>2022-11-07 11:49:22 +0100
committerFelix Held <felix-coreboot@felixheld.de>2022-12-05 14:22:39 +0000
commit803029685f96bccac13359fc616d1577508ba764 (patch)
tree6c67ba19094d2a9fe57001f0a19cc4a887bc6905 /src/mainboard/asus/p5qc
parent98c92570d9bb363740ae1b2cbbefc3c0f2404cb4 (diff)
nb/intel/x4x: Remove apic 0 from devicetree
This is added at runtime. Change-Id: I7716f8a972e2280179aa6aee00488b22413c0c73 Signed-off-by: Arthur Heymans <arthur@aheymans.xyz> Reviewed-on: https://review.coreboot.org/c/coreboot/+/69298 Reviewed-by: Kyösti Mälkki <kyosti.malkki@gmail.com> Tested-by: build bot (Jenkins) <no-reply@coreboot.org> Reviewed-by: Felix Held <felix-coreboot@felixheld.de>
Diffstat (limited to 'src/mainboard/asus/p5qc')
-rw-r--r--src/mainboard/asus/p5qc/variants/p5q/devicetree.cb7
-rw-r--r--src/mainboard/asus/p5qc/variants/p5q_pro/devicetree.cb7
-rw-r--r--src/mainboard/asus/p5qc/variants/p5q_se/devicetree.cb7
-rw-r--r--src/mainboard/asus/p5qc/variants/p5qc/devicetree.cb7
-rw-r--r--src/mainboard/asus/p5qc/variants/p5ql_pro/devicetree.cb7
5 files changed, 5 insertions, 30 deletions
diff --git a/src/mainboard/asus/p5qc/variants/p5q/devicetree.cb b/src/mainboard/asus/p5qc/variants/p5q/devicetree.cb
index d7d465508c..4b1d290a9c 100644
--- a/src/mainboard/asus/p5qc/variants/p5q/devicetree.cb
+++ b/src/mainboard/asus/p5qc/variants/p5q/devicetree.cb
@@ -1,12 +1,7 @@
# SPDX-License-Identifier: GPL-2.0-or-later
chip northbridge/intel/x4x # Northbridge
- device cpu_cluster 0 on
- ops x4x_cpu_bus_ops # APIC cluster
- chip cpu/intel/socket_LGA775
- device lapic 0 on end
- end
- end
+ device cpu_cluster 0 on ops x4x_cpu_bus_ops end # APIC cluster
device domain 0 on
ops x4x_pci_domain_ops # PCI domain
device pci 0.0 on end # Host Bridge
diff --git a/src/mainboard/asus/p5qc/variants/p5q_pro/devicetree.cb b/src/mainboard/asus/p5qc/variants/p5q_pro/devicetree.cb
index d6dbc2dd44..b1b0106699 100644
--- a/src/mainboard/asus/p5qc/variants/p5q_pro/devicetree.cb
+++ b/src/mainboard/asus/p5qc/variants/p5q_pro/devicetree.cb
@@ -1,12 +1,7 @@
# SPDX-License-Identifier: GPL-2.0-or-later
chip northbridge/intel/x4x # Northbridge
- device cpu_cluster 0 on
- ops x4x_cpu_bus_ops # APIC cluster
- chip cpu/intel/socket_LGA775
- device lapic 0 on end
- end
- end
+ device cpu_cluster 0 on ops x4x_cpu_bus_ops end # APIC cluster
device domain 0 on
ops x4x_pci_domain_ops # PCI domain
device pci 0.0 on end # Host Bridge
diff --git a/src/mainboard/asus/p5qc/variants/p5q_se/devicetree.cb b/src/mainboard/asus/p5qc/variants/p5q_se/devicetree.cb
index f099ab297d..602ef02c5b 100644
--- a/src/mainboard/asus/p5qc/variants/p5q_se/devicetree.cb
+++ b/src/mainboard/asus/p5qc/variants/p5q_se/devicetree.cb
@@ -1,12 +1,7 @@
# SPDX-License-Identifier: GPL-2.0-or-later
chip northbridge/intel/x4x # Northbridge
- device cpu_cluster 0 on
- ops x4x_cpu_bus_ops # APIC cluster
- chip cpu/intel/socket_LGA775
- device lapic 0 on end
- end
- end
+ device cpu_cluster 0 on ops x4x_cpu_bus_ops end # APIC cluster
device domain 0 on
ops x4x_pci_domain_ops # PCI domain
device pci 0.0 on end # Host Bridge
diff --git a/src/mainboard/asus/p5qc/variants/p5qc/devicetree.cb b/src/mainboard/asus/p5qc/variants/p5qc/devicetree.cb
index 54f9dcfd3e..6e7d1423e7 100644
--- a/src/mainboard/asus/p5qc/variants/p5qc/devicetree.cb
+++ b/src/mainboard/asus/p5qc/variants/p5qc/devicetree.cb
@@ -1,12 +1,7 @@
# SPDX-License-Identifier: GPL-2.0-or-later
chip northbridge/intel/x4x # Northbridge
- device cpu_cluster 0 on
- ops x4x_cpu_bus_ops # APIC cluster
- chip cpu/intel/socket_LGA775
- device lapic 0 on end
- end
- end
+ device cpu_cluster 0 on ops x4x_cpu_bus_ops end # APIC cluster
device domain 0 on
ops x4x_pci_domain_ops # PCI domain
device pci 0.0 on end # Host Bridge
diff --git a/src/mainboard/asus/p5qc/variants/p5ql_pro/devicetree.cb b/src/mainboard/asus/p5qc/variants/p5ql_pro/devicetree.cb
index f099ab297d..602ef02c5b 100644
--- a/src/mainboard/asus/p5qc/variants/p5ql_pro/devicetree.cb
+++ b/src/mainboard/asus/p5qc/variants/p5ql_pro/devicetree.cb
@@ -1,12 +1,7 @@
# SPDX-License-Identifier: GPL-2.0-or-later
chip northbridge/intel/x4x # Northbridge
- device cpu_cluster 0 on
- ops x4x_cpu_bus_ops # APIC cluster
- chip cpu/intel/socket_LGA775
- device lapic 0 on end
- end
- end
+ device cpu_cluster 0 on ops x4x_cpu_bus_ops end # APIC cluster
device domain 0 on
ops x4x_pci_domain_ops # PCI domain
device pci 0.0 on end # Host Bridge