aboutsummaryrefslogtreecommitdiff
path: root/src/mainboard/asus/kcma-d8/devicetree.cb
diff options
context:
space:
mode:
authorArthur Heymans <arthur@aheymans.xyz>2019-11-19 15:55:05 +0100
committerKyösti Mälkki <kyosti.malkki@gmail.com>2019-11-20 18:58:43 +0000
commitf2e42c4a8ec75c162251c72df8ac3da12e8a3eb9 (patch)
treefd5851ba2be3965df592355d02bce01f7dab0215 /src/mainboard/asus/kcma-d8/devicetree.cb
parentad983eeec76ecdb2aff4fb47baeee95ade012225 (diff)
mb/*/*: Drop AMDFAM10 mainboards
Relocatable ramstage, postcar stage and C_ENVIRONMENT_BOOTBLOCK are now mandatory features, which this platform lacks. Change-Id: Ic00ca18de3d73a17041a3a2839307149ad7902b2 Signed-off-by: Arthur Heymans <arthur@aheymans.xyz> Reviewed-on: https://review.coreboot.org/c/coreboot/+/36961 Reviewed-by: Kyösti Mälkki <kyosti.malkki@gmail.com> Reviewed-by: Angel Pons <th3fanbus@gmail.com> Reviewed-by: HAOUAS Elyes <ehaouas@noos.fr> Tested-by: build bot (Jenkins) <no-reply@coreboot.org>
Diffstat (limited to 'src/mainboard/asus/kcma-d8/devicetree.cb')
-rw-r--r--src/mainboard/asus/kcma-d8/devicetree.cb239
1 files changed, 0 insertions, 239 deletions
diff --git a/src/mainboard/asus/kcma-d8/devicetree.cb b/src/mainboard/asus/kcma-d8/devicetree.cb
deleted file mode 100644
index f8a2d832d3..0000000000
--- a/src/mainboard/asus/kcma-d8/devicetree.cb
+++ /dev/null
@@ -1,239 +0,0 @@
-chip northbridge/amd/amdfam10/root_complex # Root complex
- device cpu_cluster 0 on # (L)APIC cluster
- chip cpu/amd/socket_F_1207 # CPU socket
- device lapic 0 on end # Local APIC of the CPU
- end
- end
- device domain 0 on # PCI domain
- subsystemid 0x1043 0x8163 inherit
- chip northbridge/amd/amdfam10 # Northbridge / RAM controller
- register "maximum_memory_capacity" = "0x2000000000" # 128GB
- device pci 18.0 on end # Link 0 == LDT 0
- device pci 18.0 on end # Link 1 == LDT 1
- device pci 18.0 on # Link 2 == LDT 2 [SB on link 2]
- chip southbridge/amd/sr5650 # Primary southbridge
- device pci 0.0 on end # HT Root Complex 0x9600
- device pci 0.1 on end # CLKCONFIG
- device pci 0.2 on end # IOMMU
- device pci 2.0 on # PCIE P2P bridge 0x9603 (GPP1 Port0)
- # Slot # PCI E 1 / PCI E 2
- end
- device pci 3.0 off end # PCIE P2P bridge 0x960b (GPP1 Port1)
- device pci 4.0 on # PCIE P2P bridge 0x9604 (GPP3a Port0)
- # PIKE SAS
- end
- device pci 5.0 off end # PCIE P2P bridge 0x9605 (GPP3a Port1)
- device pci 6.0 off end # PCIE P2P bridge 0x9606 (GPP3a Port2)
- device pci 7.0 off end # PCIE P2P bridge 0x9607 (GPP3a Port3)
- device pci 8.0 off end # NB/SB Link P2P bridge
- device pci 9.0 on # Bridge (GPP3a Port4)
- # Onboard # NIC A
- end
- device pci a.0 on # Bridge (GPP3a Port5)
- # Onboard # NIC B
- end
- device pci b.0 on # Bridge (GPP2 Port0)
- # Slot # PCI E 4
- end
- register "gpp1_configuration" = "0" # Configuration 16:0 default
- register "gpp2_configuration" = "1" # Configuration 8:8
- register "gpp3a_configuration" = "2" # Configuration 4:1:1:0:0:0
- register "port_enable" = "0x0f1c" # Enable all ports except 0, 1, 5, 6, and 7
- register "pcie_settling_time" = "1000000" # Allow PIKE to be detected / configured
- end
- chip southbridge/amd/sb700 # Secondary southbridge
- device pci 11.0 on end # SATA
- device pci 12.0 on end # USB
- device pci 12.1 on end # USB
- device pci 12.2 on end # USB
- device pci 13.0 on end # USB
- device pci 13.1 on end # USB
- device pci 13.2 on end # USB
- device pci 14.0 on # SM
- chip drivers/generic/generic # DIMM n-0-0-0
- device i2c 50 on end
- end
- chip drivers/generic/generic # DIMM n-0-0-1
- device i2c 51 on end
- end
- chip drivers/generic/generic # DIMM n-0-1-0
- device i2c 52 on end
- end
- chip drivers/generic/generic # DIMM n-0-1-1
- device i2c 53 on end
- end
- chip drivers/generic/generic # DIMM n-1-0-0
- device i2c 54 on end
- end
- chip drivers/generic/generic # DIMM n-1-0-1
- device i2c 55 on end
- end
- chip drivers/generic/generic # DIMM n-1-1-0
- device i2c 56 on end
- end
- chip drivers/generic/generic # DIMM n-1-1-1
- device i2c 57 on end
- end
- chip drivers/i2c/w83795
- register "fanin_ctl1" = "0xff" # Enable monitoring of FANIN1 - FANIN8
- register "fanin_ctl2" = "0x00" # Connect FANIN11 - FANIN14 to alternate functions
- register "temp_ctl1" = "0x2a" # Enable monitoring of DTS, VSEN12, and VSEN13
- register "temp_ctl2" = "0x01" # Enable monitoring of TD1/TR1
- register "temp_dtse" = "0x03" # Enable DTS1 and DTS2
- register "volt_ctl1" = "0xff" # Enable monitoring of VSEN1 - VSEN8
- register "volt_ctl2" = "0xf7" # Enable monitoring of VSEN9 - VSEN11, 3VDD, 3VSB, and VBAT
- register "temp1_fan_select" = "0x00" # All fans to manual mode (no dependence on Temp1)
- register "temp2_fan_select" = "0x00" # All fans to manual mode (no dependence on Temp2)
- register "temp3_fan_select" = "0x00" # All fans to manual mode (no dependence on Temp3)
- register "temp4_fan_select" = "0x00" # All fans to manual mode (no dependence on Temp4)
- register "temp5_fan_select" = "0x00" # All fans to manual mode (no dependence on Temp5)
- register "temp6_fan_select" = "0x00" # All fans to manual mode (no dependence on Temp6)
- register "temp1_source_select" = "0x00" # Use TD1/TR1 as data source for Temp1
- register "temp2_source_select" = "0x00" # Use TD2/TR2 as data source for Temp2
- register "temp3_source_select" = "0x00" # Use TD3/TR3 as data source for Temp3
- register "temp4_source_select" = "0x00" # Use TD4/TR4 as data source for Temp4
- register "temp5_source_select" = "0x00" # Use TR5 as data source for Temp5
- register "temp6_source_select" = "0x00" # Use TR6 as data source for Temp6
- register "tr1_critical_temperature" = "85" # Set TD1/TR1 critical temperature to 85°C
- register "tr1_critical_hysteresis" = "80" # Set TD1/TR1 critical hysteresis temperature to 80°C
- register "tr1_warning_temperature" = "70" # Set TD1/TR1 warning temperature to 70°C
- register "tr1_warning_hysteresis" = "65" # Set TD1/TR1 warning hysteresis temperature to 65°C
- register "dts_critical_temperature" = "85" # Set DTS (CPU) critical temperature to 85°C
- register "dts_critical_hysteresis" = "80" # Set DTS (CPU) critical hysteresis temperature to 80°C
- register "dts_warning_temperature" = "70" # Set DTS (CPU) warning temperature to 70°C
- register "dts_warning_hysteresis" = "65" # Set DTS (CPU) warning hysteresis temperature to 65°C
- register "temp1_critical_temperature" = "80" # Set Temp1 critical temperature to 80°C
- register "temp2_critical_temperature" = "80" # Set Temp1 critical temperature to 80°C
- register "temp3_critical_temperature" = "80" # Set Temp1 critical temperature to 80°C
- register "temp4_critical_temperature" = "80" # Set Temp1 critical temperature to 80°C
- register "temp5_critical_temperature" = "80" # Set Temp1 critical temperature to 80°C
- register "temp6_critical_temperature" = "80" # Set Temp1 critical temperature to 80°C
- register "temp1_target_temperature" = "80" # Set Temp1 target temperature to 80°C
- register "temp2_target_temperature" = "80" # Set Temp1 target temperature to 80°C
- register "temp3_target_temperature" = "80" # Set Temp1 target temperature to 80°C
- register "temp4_target_temperature" = "80" # Set Temp1 target temperature to 80°C
- register "temp5_target_temperature" = "80" # Set Temp1 target temperature to 80°C
- register "temp6_target_temperature" = "80" # Set Temp1 target temperature to 80°C
- register "fan1_nonstop" = "7" # Set Fan 1 minimum speed
- register "fan2_nonstop" = "7" # Set Fan 2 minimum speed
- register "fan3_nonstop" = "7" # Set Fan 3 minimum speed
- register "fan4_nonstop" = "7" # Set Fan 4 minimum speed
- register "fan5_nonstop" = "7" # Set Fan 5 minimum speed
- register "fan6_nonstop" = "7" # Set Fan 6 minimum speed
- register "fan7_nonstop" = "7" # Set Fan 7 minimum speed
- register "fan8_nonstop" = "7" # Set Fan 8 minimum speed
- register "default_speed" = "100" # All fans to full speed on power up
- register "fan1_duty" = "100" # Fan 1 to full speed
- register "fan2_duty" = "100" # Fan 2 to full speed
- register "fan3_duty" = "100" # Fan 3 to full speed
- register "fan4_duty" = "100" # Fan 4 to full speed
- register "fan5_duty" = "100" # Fan 5 to full speed
- register "fan6_duty" = "100" # Fan 6 to full speed
- register "fan7_duty" = "100" # Fan 7 to full speed
- register "fan8_duty" = "100" # Fan 8 to full speed
- register "vcore1_high_limit_mv" = "1500" # VCORE1 (Node 0) high limit to 1.5V
- register "vcore1_low_limit_mv" = "900" # VCORE1 (Node 0) low limit to 0.9V
- register "vcore2_high_limit_mv" = "1500" # VCORE2 (Node 1) high limit to 1.5V
- register "vcore2_low_limit_mv" = "900" # VCORE2 (Node 1) low limit to 0.9V
- register "vsen3_high_limit_mv" = "1600" # VSEN1 (Node 0 RAM voltage) high limit to 1.6V
- register "vsen3_low_limit_mv" = "1100" # VSEN1 (Node 0 RAM voltage) low limit to 1.1V
- register "vsen4_high_limit_mv" = "1600" # VSEN2 (Node 1 RAM voltage) high limit to 1.6V
- register "vsen4_low_limit_mv" = "1100" # VSEN2 (Node 1 RAM voltage) low limit to 1.1V
- register "vsen5_high_limit_mv" = "1250" # VSEN5 (Node 0 HT link voltage) high limit to 1.25V
- register "vsen5_low_limit_mv" = "1150" # VSEN5 (Node 0 HT link voltage) low limit to 1.15V
- register "vsen6_high_limit_mv" = "1250" # VSEN6 (Node 1 HT link voltage) high limit to 1.25V
- register "vsen6_low_limit_mv" = "1150" # VSEN6 (Node 1 HT link voltage) low limit to 1.15V
- register "vsen7_high_limit_mv" = "1150" # VSEN7 (Northbridge core voltage) high limit to 1.15V
- register "vsen7_low_limit_mv" = "1050" # VSEN7 (Northbridge core voltage) low limit to 1.05V
- register "vsen8_high_limit_mv" = "1900" # VSEN8 (+1.8V) high limit to 1.9V
- register "vsen8_low_limit_mv" = "1700" # VSEN8 (+1.8V) low limit to 1.7V
- register "vsen9_high_limit_mv" = "1250" # VSEN9 (+1.2V) high limit to 1.25V
- register "vsen9_low_limit_mv" = "1150" # VSEN9 (+1.2V) low limit to 1.15V
- register "vsen10_high_limit_mv" = "1150" # VSEN10 (+1.1V) high limit to 1.15V
- register "vsen10_low_limit_mv" = "1050" # VSEN10 (+1.1V) low limit to 1.05V
- register "vsen11_high_limit_mv" = "1625" # VSEN11 (5VSB, scaling factor ~3.2) high limit to 5.2V
- register "vsen11_low_limit_mv" = "1500" # VSEN11 (5VSB, scaling factor ~3.2) low limit to 4.8V
- register "vsen12_high_limit_mv" = "1083" # VSEN12 (+12V, scaling factor ~12) high limit to 13V
- register "vsen12_low_limit_mv" = "917" # VSEN12 (+12V, scaling factor ~12) low limit to 11V
- register "vsen13_high_limit_mv" = "1625" # VSEN13 (+5V, scaling factor ~3.2) high limit to 5.2V
- register "vsen13_low_limit_mv" = "1500" # VSEN13 (+5V, scaling factor ~3.2) low limit to 4.8V
- register "vdd_high_limit_mv" = "3500" # 3VDD high limit to 3.5V
- register "vdd_low_limit_mv" = "3100" # 3VDD low limit to 3.1V
- register "vsb_high_limit_mv" = "3500" # 3VSB high limit to 3.5V
- register "vsb_low_limit_mv" = "3100" # 3VSB low limit to 3.1V
- register "vbat_high_limit_mv" = "3500" # VBAT (+3V) high limit to 3.5V
- register "vbat_low_limit_mv" = "2500" # VBAT (+3V) low limit to 2.5V
- register "smbus_aux" = "1" # Device located on auxiliary SMBUS controller
- device i2c 0x2f on end
- end
- end
- device pci 14.1 on end # IDE 0x439c
- device pci 14.2 on end # HDA 0x4383 (ASUS MIO add-on card)
- device pci 14.3 on # LPC 0x439d (SMBUS primary controller)
- chip superio/winbond/w83667hg-a # Super I/O
- device pnp 2e.0 off end # FDC; Not available on the KCMA-D8
- device pnp 2e.1 off end # LPT1; Not available on the KCMA-D8
- device pnp 2e.2 on # COM1
- io 0x60 = 0x3f8
- irq 0x70 = 4
- end
- device pnp 2e.3 on # COM2
- io 0x60 = 0x2f8
- irq 0x70 = 3
- end
- device pnp 2e.5 on # PS/2 keyboard & mouse
- io 0x60 = 0x60
- io 0x62 = 0x64
- irq 0x70 = 1
- irq 0x72 = 12
- end
- device pnp 2e.106 off end # SPI: Not available on the KCMA-D8
- device pnp 2e.107 off end # GIPO6
- device pnp 2e.207 off end # GIPO7
- device pnp 2e.307 off end # GIPO8
- device pnp 2e.407 off end # GIPO9
- device pnp 2e.8 off end # WDT
- device pnp 2e.108 off end # GPIO 1
- device pnp 2e.9 off end # GPIO2
- device pnp 2e.109 off end # GPIO3
- device pnp 2e.209 off end # GPIO4
- device pnp 2e.309 off end # GPIO5
- device pnp 2e.a on end # ACPI
- device pnp 2e.b on # HW Monitor
- io 0x60 = 0x290
- # IRQ purposefully not assigned to prevent lockups
- end
- device pnp 2e.c off end # PECI
- device pnp 2e.d off end # VID_BUSSEL
- device pnp 2e.f off end # GPIO_PP_OD
- end
- end
- device pci 14.4 on # Bridge
- device pci 1.0 on # Slot
- # Slot # PCI 0
- end
- device pci 2.0 on # Slot
- # Slot # PCI 1
- end
- device pci 3.0 on # Slot
- # Slot # PCI 2
- end
- device pci 5.0 on end # VGA
- end
- device pci 14.5 on end # USB OHCI2 0x4399
- end
- end
- device pci 18.1 on end
- device pci 18.2 on end
- device pci 18.3 on end
- device pci 18.4 on end
- device pci 18.5 on end
- device pci 19.0 on end # Socket 1 node 0
- device pci 19.1 on end
- device pci 19.2 on end
- device pci 19.3 on end
- device pci 19.4 on end
- device pci 19.5 on end
- end
- end
-end