summaryrefslogtreecommitdiff
path: root/src/home/inverter
diff options
context:
space:
mode:
Diffstat (limited to 'src/home/inverter')
-rw-r--r--src/home/inverter/__init__.py9
-rw-r--r--src/home/inverter/monitor.py80
-rw-r--r--src/home/inverter/types.py55
3 files changed, 85 insertions, 59 deletions
diff --git a/src/home/inverter/__init__.py b/src/home/inverter/__init__.py
index 967ddff..8831ef3 100644
--- a/src/home/inverter/__init__.py
+++ b/src/home/inverter/__init__.py
@@ -1,10 +1,3 @@
-from .monitor import (
- ChargingEvent,
- InverterMonitor,
- BatteryState,
- BatteryPowerDirection,
- ACMode,
- ACPresentEvent
-)
+from .monitor import InverterMonitor
from .inverter_wrapper import wrapper_instance
from .util import beautify_table
diff --git a/src/home/inverter/monitor.py b/src/home/inverter/monitor.py
index 2fcd55a..898c998 100644
--- a/src/home/inverter/monitor.py
+++ b/src/home/inverter/monitor.py
@@ -1,7 +1,7 @@
import logging
import time
-from enum import Enum, auto
+from .types import *
from threading import Thread
from typing import Callable, Optional
from .inverter_wrapper import wrapper_instance as inverter
@@ -12,55 +12,6 @@ from ..config import config
logger = logging.getLogger(__name__)
-class BatteryPowerDirection(Enum):
- DISCHARGING = auto()
- CHARGING = auto()
- DO_NOTHING = auto()
-
-
-class ChargingEvent(Enum):
- AC_CHARGING_UNAVAILABLE_BECAUSE_SOLAR = auto()
- AC_NOT_CHARGING = auto()
- AC_CHARGING_STARTED = auto()
- AC_DISCONNECTED = auto()
- AC_CURRENT_CHANGED = auto()
- AC_MOSTLY_CHARGED = auto()
- AC_CHARGING_FINISHED = auto()
-
- UTIL_CHARGING_STARTED = auto()
- UTIL_CHARGING_STOPPED = auto()
- UTIL_CHARGING_STOPPED_SOLAR = auto()
-
-
-class ACPresentEvent(Enum):
- CONNECTED = auto()
- DISCONNECTED = auto()
-
-
-class ChargingState(Enum):
- NOT_CHARGING = auto()
- AC_BUT_SOLAR = auto()
- AC_WAITING = auto()
- AC_OK = auto()
- AC_DONE = auto()
-
-
-class CurrentChangeDirection(Enum):
- UP = auto()
- DOWN = auto()
-
-
-class BatteryState(Enum):
- NORMAL = auto()
- LOW = auto()
- CRITICAL = auto()
-
-
-class ACMode(Enum):
- GENERATOR = 'generator'
- UTILITIES = 'utilities'
-
-
def _pd_from_string(pd: str) -> BatteryPowerDirection:
if pd == 'Discharge':
return BatteryPowerDirection.DISCHARGING
@@ -94,6 +45,8 @@ class InverterMonitor(Thread):
battery_event_handler: Optional[Callable]
util_event_handler: Optional[Callable]
error_handler: Optional[Callable]
+ osp_change_cb: Optional[Callable]
+ osp: Optional[OutputSourcePriority]
def __init__(self):
super().__init__()
@@ -102,12 +55,14 @@ class InverterMonitor(Thread):
self.interrupted = False
self.min_allowed_current = 0
self.ac_mode = None
+ self.osp = None
# Event handlers for the bot.
self.charging_event_handler = None
self.battery_event_handler = None
self.util_event_handler = None
self.error_handler = None
+ self.osp_change_cb = None
# Currents list, defined in the bot config.
self.currents = cfg.gen_currents
@@ -156,6 +111,12 @@ class InverterMonitor(Thread):
self.min_allowed_current = min(allowed_currents)
+ # Reading rated configuration
+ rated = inverter.exec('get-rated')['data']
+ self.osp = OutputSourcePriority.SolarBatteryUtility \
+ if rated['output_source_priority'] == 'Solar-Battery-Utility' \
+ else OutputSourcePriority.SolarUtilityBattery
+
# Read data and run implemented programs every 2 seconds.
while not self.interrupted:
try:
@@ -167,6 +128,7 @@ class InverterMonitor(Thread):
ac = gs['grid_voltage']['value'] > 0 or gs['grid_freq']['value'] > 0
solar = gs['pv1_input_voltage']['value'] > 0 or gs['pv2_input_voltage']['value'] > 0
+ solar_input = gs['pv1_input_power']['value']
v = float(gs['battery_voltage']['value'])
load_watts = int(gs['ac_output_active_power']['value'])
pd = _pd_from_string(gs['battery_power_direction'])
@@ -177,7 +139,7 @@ class InverterMonitor(Thread):
self.gen_charging_program(ac, solar, v, pd)
elif self.ac_mode == ACMode.UTILITIES:
- self.utilities_monitoring_program(ac, solar, pd)
+ self.utilities_monitoring_program(ac, solar, v, load_watts, solar_input, pd)
if not ac or pd != BatteryPowerDirection.CHARGING:
# if AC is disconnected or not charging, run the low voltage checking program
@@ -195,6 +157,9 @@ class InverterMonitor(Thread):
def utilities_monitoring_program(self,
ac: bool, # whether AC is connected
solar: bool, # whether MPPT is active
+ v: float, # battery voltage
+ load_watts: int, # load, wh
+ solar_input: int, # input from solar panels, wh
pd: BatteryPowerDirection # current power direction
):
pd_event_send = False
@@ -204,6 +169,15 @@ class InverterMonitor(Thread):
self.charging_event_handler(ChargingEvent.UTIL_CHARGING_STOPPED_SOLAR)
pd_event_send = True
+ if solar:
+ if v <= 48 and self.osp == OutputSourcePriority.SolarBatteryUtility:
+ self.osp_change_cb(OutputSourcePriority.SolarUtilityBattery, solar_input=solar_input, v=v)
+ self.osp = OutputSourcePriority.SolarUtilityBattery
+
+ if self.osp == OutputSourcePriority.SolarUtilityBattery and solar_input >= 900:
+ self.osp_change_cb(OutputSourcePriority.SolarBatteryUtility, solar_input=solar_input, v=v)
+ self.osp = OutputSourcePriority.SolarBatteryUtility
+
if self.util_ac_present is None or ac != self.util_ac_present:
self.util_event_handler(ACPresentEvent.CONNECTED if ac else ACPresentEvent.DISCONNECTED)
self.util_ac_present = ac
@@ -213,6 +187,7 @@ class InverterMonitor(Thread):
if not pd_event_send and not solar:
if pd == BatteryPowerDirection.CHARGING:
self.charging_event_handler(ChargingEvent.UTIL_CHARGING_STARTED)
+
elif pd == BatteryPowerDirection.DISCHARGING:
self.charging_event_handler(ChargingEvent.UTIL_CHARGING_STOPPED)
@@ -493,6 +468,9 @@ class InverterMonitor(Thread):
def set_error_handler(self, handler: Callable):
self.error_handler = handler
+ def set_osp_need_change_callback(self, cb: Callable):
+ self.osp_change_cb = cb
+
def set_ac_mode(self, mode: ACMode):
self.ac_mode = mode
diff --git a/src/home/inverter/types.py b/src/home/inverter/types.py
new file mode 100644
index 0000000..0292c15
--- /dev/null
+++ b/src/home/inverter/types.py
@@ -0,0 +1,55 @@
+from enum import Enum, auto
+
+
+class BatteryPowerDirection(Enum):
+ DISCHARGING = auto()
+ CHARGING = auto()
+ DO_NOTHING = auto()
+
+
+class ChargingEvent(Enum):
+ AC_CHARGING_UNAVAILABLE_BECAUSE_SOLAR = auto()
+ AC_NOT_CHARGING = auto()
+ AC_CHARGING_STARTED = auto()
+ AC_DISCONNECTED = auto()
+ AC_CURRENT_CHANGED = auto()
+ AC_MOSTLY_CHARGED = auto()
+ AC_CHARGING_FINISHED = auto()
+
+ UTIL_CHARGING_STARTED = auto()
+ UTIL_CHARGING_STOPPED = auto()
+ UTIL_CHARGING_STOPPED_SOLAR = auto()
+
+
+class ACPresentEvent(Enum):
+ CONNECTED = auto()
+ DISCONNECTED = auto()
+
+
+class ChargingState(Enum):
+ NOT_CHARGING = auto()
+ AC_BUT_SOLAR = auto()
+ AC_WAITING = auto()
+ AC_OK = auto()
+ AC_DONE = auto()
+
+
+class CurrentChangeDirection(Enum):
+ UP = auto()
+ DOWN = auto()
+
+
+class BatteryState(Enum):
+ NORMAL = auto()
+ LOW = auto()
+ CRITICAL = auto()
+
+
+class ACMode(Enum):
+ GENERATOR = 'generator'
+ UTILITIES = 'utilities'
+
+
+class OutputSourcePriority(Enum):
+ SolarUtilityBattery = 'SUB'
+ SolarBatteryUtility = 'SBU' \ No newline at end of file