diff options
author | Evgeny Zinoviev <me@ch1p.io> | 2022-10-22 19:13:36 +0300 |
---|---|---|
committer | Evgeny Zinoviev <me@ch1p.io> | 2022-10-22 19:13:36 +0300 |
commit | ff73c73a2cc9764dba3dbcabce68eca3b028b03c (patch) | |
tree | 0296d182b12aa2edb76d1a6ec79a48fe6371aff9 /src/home | |
parent | 3bac4b316dc275c1c22b93cde5ebac87df1d3234 (diff) |
inverter_bot: update osp util program
Diffstat (limited to 'src/home')
-rw-r--r-- | src/home/inverter/__init__.py | 9 | ||||
-rw-r--r-- | src/home/inverter/monitor.py | 80 | ||||
-rw-r--r-- | src/home/inverter/types.py | 55 |
3 files changed, 85 insertions, 59 deletions
diff --git a/src/home/inverter/__init__.py b/src/home/inverter/__init__.py index 967ddff..8831ef3 100644 --- a/src/home/inverter/__init__.py +++ b/src/home/inverter/__init__.py @@ -1,10 +1,3 @@ -from .monitor import ( - ChargingEvent, - InverterMonitor, - BatteryState, - BatteryPowerDirection, - ACMode, - ACPresentEvent -) +from .monitor import InverterMonitor from .inverter_wrapper import wrapper_instance from .util import beautify_table diff --git a/src/home/inverter/monitor.py b/src/home/inverter/monitor.py index 2fcd55a..898c998 100644 --- a/src/home/inverter/monitor.py +++ b/src/home/inverter/monitor.py @@ -1,7 +1,7 @@ import logging import time -from enum import Enum, auto +from .types import * from threading import Thread from typing import Callable, Optional from .inverter_wrapper import wrapper_instance as inverter @@ -12,55 +12,6 @@ from ..config import config logger = logging.getLogger(__name__) -class BatteryPowerDirection(Enum): - DISCHARGING = auto() - CHARGING = auto() - DO_NOTHING = auto() - - -class ChargingEvent(Enum): - AC_CHARGING_UNAVAILABLE_BECAUSE_SOLAR = auto() - AC_NOT_CHARGING = auto() - AC_CHARGING_STARTED = auto() - AC_DISCONNECTED = auto() - AC_CURRENT_CHANGED = auto() - AC_MOSTLY_CHARGED = auto() - AC_CHARGING_FINISHED = auto() - - UTIL_CHARGING_STARTED = auto() - UTIL_CHARGING_STOPPED = auto() - UTIL_CHARGING_STOPPED_SOLAR = auto() - - -class ACPresentEvent(Enum): - CONNECTED = auto() - DISCONNECTED = auto() - - -class ChargingState(Enum): - NOT_CHARGING = auto() - AC_BUT_SOLAR = auto() - AC_WAITING = auto() - AC_OK = auto() - AC_DONE = auto() - - -class CurrentChangeDirection(Enum): - UP = auto() - DOWN = auto() - - -class BatteryState(Enum): - NORMAL = auto() - LOW = auto() - CRITICAL = auto() - - -class ACMode(Enum): - GENERATOR = 'generator' - UTILITIES = 'utilities' - - def _pd_from_string(pd: str) -> BatteryPowerDirection: if pd == 'Discharge': return BatteryPowerDirection.DISCHARGING @@ -94,6 +45,8 @@ class InverterMonitor(Thread): battery_event_handler: Optional[Callable] util_event_handler: Optional[Callable] error_handler: Optional[Callable] + osp_change_cb: Optional[Callable] + osp: Optional[OutputSourcePriority] def __init__(self): super().__init__() @@ -102,12 +55,14 @@ class InverterMonitor(Thread): self.interrupted = False self.min_allowed_current = 0 self.ac_mode = None + self.osp = None # Event handlers for the bot. self.charging_event_handler = None self.battery_event_handler = None self.util_event_handler = None self.error_handler = None + self.osp_change_cb = None # Currents list, defined in the bot config. self.currents = cfg.gen_currents @@ -156,6 +111,12 @@ class InverterMonitor(Thread): self.min_allowed_current = min(allowed_currents) + # Reading rated configuration + rated = inverter.exec('get-rated')['data'] + self.osp = OutputSourcePriority.SolarBatteryUtility \ + if rated['output_source_priority'] == 'Solar-Battery-Utility' \ + else OutputSourcePriority.SolarUtilityBattery + # Read data and run implemented programs every 2 seconds. while not self.interrupted: try: @@ -167,6 +128,7 @@ class InverterMonitor(Thread): ac = gs['grid_voltage']['value'] > 0 or gs['grid_freq']['value'] > 0 solar = gs['pv1_input_voltage']['value'] > 0 or gs['pv2_input_voltage']['value'] > 0 + solar_input = gs['pv1_input_power']['value'] v = float(gs['battery_voltage']['value']) load_watts = int(gs['ac_output_active_power']['value']) pd = _pd_from_string(gs['battery_power_direction']) @@ -177,7 +139,7 @@ class InverterMonitor(Thread): self.gen_charging_program(ac, solar, v, pd) elif self.ac_mode == ACMode.UTILITIES: - self.utilities_monitoring_program(ac, solar, pd) + self.utilities_monitoring_program(ac, solar, v, load_watts, solar_input, pd) if not ac or pd != BatteryPowerDirection.CHARGING: # if AC is disconnected or not charging, run the low voltage checking program @@ -195,6 +157,9 @@ class InverterMonitor(Thread): def utilities_monitoring_program(self, ac: bool, # whether AC is connected solar: bool, # whether MPPT is active + v: float, # battery voltage + load_watts: int, # load, wh + solar_input: int, # input from solar panels, wh pd: BatteryPowerDirection # current power direction ): pd_event_send = False @@ -204,6 +169,15 @@ class InverterMonitor(Thread): self.charging_event_handler(ChargingEvent.UTIL_CHARGING_STOPPED_SOLAR) pd_event_send = True + if solar: + if v <= 48 and self.osp == OutputSourcePriority.SolarBatteryUtility: + self.osp_change_cb(OutputSourcePriority.SolarUtilityBattery, solar_input=solar_input, v=v) + self.osp = OutputSourcePriority.SolarUtilityBattery + + if self.osp == OutputSourcePriority.SolarUtilityBattery and solar_input >= 900: + self.osp_change_cb(OutputSourcePriority.SolarBatteryUtility, solar_input=solar_input, v=v) + self.osp = OutputSourcePriority.SolarBatteryUtility + if self.util_ac_present is None or ac != self.util_ac_present: self.util_event_handler(ACPresentEvent.CONNECTED if ac else ACPresentEvent.DISCONNECTED) self.util_ac_present = ac @@ -213,6 +187,7 @@ class InverterMonitor(Thread): if not pd_event_send and not solar: if pd == BatteryPowerDirection.CHARGING: self.charging_event_handler(ChargingEvent.UTIL_CHARGING_STARTED) + elif pd == BatteryPowerDirection.DISCHARGING: self.charging_event_handler(ChargingEvent.UTIL_CHARGING_STOPPED) @@ -493,6 +468,9 @@ class InverterMonitor(Thread): def set_error_handler(self, handler: Callable): self.error_handler = handler + def set_osp_need_change_callback(self, cb: Callable): + self.osp_change_cb = cb + def set_ac_mode(self, mode: ACMode): self.ac_mode = mode diff --git a/src/home/inverter/types.py b/src/home/inverter/types.py new file mode 100644 index 0000000..0292c15 --- /dev/null +++ b/src/home/inverter/types.py @@ -0,0 +1,55 @@ +from enum import Enum, auto + + +class BatteryPowerDirection(Enum): + DISCHARGING = auto() + CHARGING = auto() + DO_NOTHING = auto() + + +class ChargingEvent(Enum): + AC_CHARGING_UNAVAILABLE_BECAUSE_SOLAR = auto() + AC_NOT_CHARGING = auto() + AC_CHARGING_STARTED = auto() + AC_DISCONNECTED = auto() + AC_CURRENT_CHANGED = auto() + AC_MOSTLY_CHARGED = auto() + AC_CHARGING_FINISHED = auto() + + UTIL_CHARGING_STARTED = auto() + UTIL_CHARGING_STOPPED = auto() + UTIL_CHARGING_STOPPED_SOLAR = auto() + + +class ACPresentEvent(Enum): + CONNECTED = auto() + DISCONNECTED = auto() + + +class ChargingState(Enum): + NOT_CHARGING = auto() + AC_BUT_SOLAR = auto() + AC_WAITING = auto() + AC_OK = auto() + AC_DONE = auto() + + +class CurrentChangeDirection(Enum): + UP = auto() + DOWN = auto() + + +class BatteryState(Enum): + NORMAL = auto() + LOW = auto() + CRITICAL = auto() + + +class ACMode(Enum): + GENERATOR = 'generator' + UTILITIES = 'utilities' + + +class OutputSourcePriority(Enum): + SolarUtilityBattery = 'SUB' + SolarBatteryUtility = 'SBU'
\ No newline at end of file |