Enable aspeed's function that port 80h direct to GPIO for LED display,
refer to section 9.4 Port 80h Direct to GPIO Guide of aspeed's
Application Design Guide, also configure GPIO to UART for output
serial console messages.
Tested=Check if port 80h LED debug card can display POST codes at
early stage, and serial console can see the related messages.
Change-Id: I087d5a81b881533b4550c193e4e9720a134fb8e7
Signed-off-by: BryantOu <Bryant.Ou.Q@gmail.com>
Reviewed-on: https://review.coreboot.org/c/coreboot/+/40481
Reviewed-by: Patrick Rudolph <patrick.rudolph@9elements.com>
Reviewed-by: Andrey Petrov <andrey.petrov@gmail.com>
Tested-by: build bot (Jenkins) <no-reply@coreboot.org>
|
|
Change-Id: I8930e96e5f2c45b8658dc4dfe1ab57d573e7b26f
Fixes: b75bcc978a ("mb/ocp/tiogapass: Properly configure early serial output")
Signed-off-by: Paul Menzel <pmenzel@molgen.mpg.de>
Reviewed-on: https://review.coreboot.org/c/coreboot/+/39870
Tested-by: build bot (Jenkins) <no-reply@coreboot.org>
Reviewed-by: Angel Pons <th3fanbus@gmail.com>
Reviewed-by: Andrey Petrov <andrey.petrov@gmail.com>
|
|
Tioga Pass comes with AST2500 BMC which offers SuperIO functionality.
However we currently do not configure/enable SuperIO chip. As a result
system boots pretty silently on cold boot. Then FSP configures SuperIO
and resets the system so on next boot serial console does work. This
makes debugging difficult because pre-FSP output is invisible.
This patch enables bootblock to properly configure desired BMC SuperIO
port so early serial output is visible.
TEST=do a cold boot on OCP Tioga Pass, observe bootblock output starting
from bootblock.
Change-Id: Iff8e6a862858d733f529bb9b8c65e22e5ec6b521
Signed-off-by: Andrey Petrov <anpetrov@fb.com>
Reviewed-on: https://review.coreboot.org/c/coreboot/+/39782
Tested-by: build bot (Jenkins) <no-reply@coreboot.org>
Reviewed-by: Maxim Polyakov <max.senia.poliak@gmail.com>
|