Age | Commit message (Collapse) | Author |
|
According to the datasheet the RTC needs a power rising slope of no more
than 100µs/V to ensure a correct power-on reset. If the mainboard that
hosts the RTC cannot guarantee this, a software reset sequence is needed
in the case where the battery was drained completely.
As the rising slope of the power supply depends on so many parameters
and is highly mainboard specific, refactor the initialization code to
perform a software reset every time a power loss event is recognized by
the RTC.
Change-Id: If64d672e51667523058041bd00e1e50ac047143d
Signed-off-by: Werner Zeh <werner.zeh@siemens.com>
Reviewed-on: https://review.coreboot.org/20412
Tested-by: build bot (Jenkins) <no-reply@coreboot.org>
Reviewed-by: Martin Roth <martinroth@google.com>
|
|
The RTC RX6110SA has several configuration options which might be
interesting to set. To make this setup independent of the driver itself
but let it still be configurable on mainboard level, add more
configuration options to the chip driver.
Change-Id: I7f8b2aa7cd001a887f271be36f655e10e60e778b
Signed-off-by: Werner Zeh <werner.zeh@siemens.com>
Reviewed-on: https://review.coreboot.org/20084
Tested-by: build bot (Jenkins) <no-reply@coreboot.org>
Reviewed-by: Mario Scheithauer <mario.scheithauer@siemens.com>
|
|
The driver for the RTC RX6110SA is designed to be used with I2C bus.
This patch adds the possibility to use SMBus operations to access the
RTC. For this purpose the Kconfig switch RX6110SA_USE_SMBUS is added. It
is not enabled per default so that I2C will be used. One can set this
switch on board level to use SMBus instead.
Change-Id: I4827ae2c544e8002399d94a1159acacd8176c5e9
Signed-off-by: Werner Zeh <werner.zeh@siemens.com>
Reviewed-on: https://review.coreboot.org/19978
Reviewed-by: Aaron Durbin <adurbin@chromium.org>
Tested-by: build bot (Jenkins) <no-reply@coreboot.org>
|
|
This driver enables the usage of the external RTC chip RX6110 SA
(http://www5.epsondevice.com/en/products/i2c/rx6110sab.html) which is
connected to the I2C bus. The I2C address of this device is fixed. One
can change parameters in the device tree so that the used setup can be
adapted to match the configuration of the device on the mainboard.
Change-Id: I1290a10c2d5ad76a317c99c8b92a013309a605d6
Signed-off-by: Mario Scheithauer <mario.scheithauer@siemens.com>
Reviewed-on: https://review.coreboot.org/19625
Tested-by: build bot (Jenkins) <no-reply@coreboot.org>
Reviewed-by: Werner Zeh <werner.zeh@siemens.com>
|