-rw-r--r--src/mainboard/google/hatch/variants/noibat/overridetree.cb34
1 files changed, 18 insertions, 16 deletions
diff --git a/src/mainboard/google/hatch/variants/noibat/overridetree.cb b/src/mainboard/google/hatch/variants/noibat/overridetree.cb
index de49462d06..e206ea57e5 100644
--- a/src/mainboard/google/hatch/variants/noibat/overridetree.cb
+++ b/src/mainboard/google/hatch/variants/noibat/overridetree.cb
@@ -1,4 +1,8 @@
chip soc/intel/cannonlake
+ register "power_limits_config" = "{
+ .tdp_pl1_override = 15,
+ .tdp_pl2_override = 51,
+ }"
# Auto-switch between X4 NVMe and X2 NVMe.
register "TetonGlacierMode" = "1"
@@ -197,29 +201,27 @@ chip soc/intel/cannonlake
chip drivers/intel/dptf
## Active Policy
register "policies.active[0]" = "{.target=DPTF_CPU,
- .thresholds={TEMP_PCT(90, 85),
- TEMP_PCT(85, 75),
- TEMP_PCT(80, 65),
- TEMP_PCT(75, 55),
- TEMP_PCT(70, 45),}}"
+ .thresholds={TEMP_PCT(94, 0),}}"
register "policies.active[1]" = "{.target=DPTF_TEMP_SENSOR_0,
- .thresholds={TEMP_PCT(50, 85),
- TEMP_PCT(47, 75),
- TEMP_PCT(45, 65),
- TEMP_PCT(42, 55),
- TEMP_PCT(39, 45),}}"
+ .thresholds={TEMP_PCT(65, 90),
+ TEMP_PCT(52, 80),
+ TEMP_PCT(50, 70),
+ TEMP_PCT(48, 60),
+ TEMP_PCT(46, 50),
+ TEMP_PCT(44, 40),
+ TEMP_PCT(42, 0),}}"
## Passive Policy
- register "policies.passive[0]" = "DPTF_PASSIVE(CPU, CPU, 93, 5000)"
- register "policies.passive[1]" = "DPTF_PASSIVE(CPU, TEMP_SENSOR_0, 65, 6000)"
+ register "policies.passive[0]" = "DPTF_PASSIVE(CPU, CPU, 95, 5000)"
+ register "policies.passive[1]" = "DPTF_PASSIVE(CPU, TEMP_SENSOR_0, 68, 5000)"
## Critical Policy
register "policies.critical[0]" = "DPTF_CRITICAL(CPU, 100, SHUTDOWN)"
- register "policies.critical[1]" = "DPTF_CRITICAL(TEMP_SENSOR_0, 75, SHUTDOWN)"
+ register "policies.critical[1]" = "DPTF_CRITICAL(TEMP_SENSOR_0, 78, SHUTDOWN)"
## Power Limits Control
# PL1 is fixed at 15W, avg over 28-32s interval
- # 25-64W PL2 in 1000mW increments, avg over 28-32s interval
+ # 15-51W PL2 in 1000mW increments, avg over 28-32s interval
register "controls.power_limits.pl1" = "{
.min_power = 15000,
.max_power = 15000,
@@ -227,8 +229,8 @@ chip soc/intel/cannonlake
.time_window_max = 32 * MSECS_PER_SEC,
.granularity = 200,}"
register "controls.power_limits.pl2" = "{
- .min_power = 25000,
- .max_power = 64000,
+ .min_power = 15000,
+ .max_power = 51000,
.time_window_min = 28 * MSECS_PER_SEC,
.time_window_max = 32 * MSECS_PER_SEC,
.granularity = 1000,}"