diff --git a/src/soc/intel/common/block/cpu/Kconfig b/src/soc/intel/common/block/cpu/Kconfig
new file mode 100644
index 0000000000..7b78c53ea7
--- /dev/null
+++ b/src/soc/intel/common/block/cpu/Kconfig
@@ -0,0 +1,32 @@
+config SOC_INTEL_COMMON_BLOCK_CAR
+ bool
+ default n
+ help
+ This option allows you to select how cache-as-ram (CAR) is set up.
+
+config INTEL_CAR_NEM
+ bool
+ default n
+ help
+ Traditionally, CAR is set up by using Non-Evict mode. This method
+ does not allow CAR and cache to co-exist, because cache fills are
+ blocked in NEM.
+
+config INTEL_CAR_CQOS
+ bool
+ default n
+ help
+ Cache Quality of Service allows more fine-grained control of cache
+ usage. As result, it is possible to set up a portion of L2 cache for
+ CAR and use the remainder for actual caching.
+
+config INTEL_CAR_NEM_ENHANCED
+ bool
+ default n
+ help
+ A current limitation of NEM (Non-Evict mode) is that code and data sizes
+ are derived from the requirement to not write out any modified cache line.
+ With NEM, if there is no physical memory behind the cached area,
+ the modified data will be lost and NEM results will be inconsistent.
+ ENHANCED NEM guarantees that modified data is always
+ kept in cache while clean data is replaced.