drivers/tpm: Force enable long IRQ pulses for Ti50 versions under 0.15.
Only Cr50 versions starting at 0.5.5 support long IRQ pulses, so this feature is enabled based on the value of the board_cfg register (see CB:61722). However, Ti50 versions below 0.0.15 don't support the board_cfg register, and trying to access it will cause I2C errors (see CB:63011). Also, all Ti50 versions only support long IRQ pulses. Therefore, add a workaround to force enable long IRQ pulses for boards using Ti50 versions under 0.0.15, instead of enabling it based on board_cfg. This workaround will be removed once all Ti50 stocks are updated to 0.0.15 or higher. BUG=b:225941781 TEST=Boot nivviks and nereid to OS with Ti50 0.0.14 and check there are none of these I2C errors: [ERROR] I2C stop bit not received [ERROR] cr50_i2c_read: Address write failed [ERROR] cr50_i2c_tis_status: Failed to read status Change-Id: Iaba71461d8ec79e8d6efddbd505339cdf1176485 Signed-off-by: Reka Norman <rekanorman@google.com> Reviewed-on: https://review.coreboot.org/c/coreboot/+/63160 Reviewed-by: Eric Lai <eric_lai@quanta.corp-partner.google.com> Reviewed-by: Kangheui Won <khwon@chromium.org> Tested-by: build bot (Jenkins) <no-reply@coreboot.org>