summaryrefslogtreecommitdiff
path: root/src
diff options
context:
space:
mode:
authorElyes HAOUAS <ehaouas@noos.fr>2020-10-08 09:39:22 +0200
committerMichael Niewöhner <foss@mniewoehner.de>2021-02-10 17:46:38 +0000
commitb4b4fa5b2fad4d5dfbfd8cd7b0d3d17b686fb0e1 (patch)
treea79ea2258eeb366bc0c4ab058a5c42070b9c71d4 /src
parente166cb38bf8f01944bff435b5fef79f9f0b7a50d (diff)
mb/intel/wtm2: Convert to ASL 2.0 syntax
Generated 'build/dsdt.dsl' files are same. Change-Id: Id68623cfb57e889e60d66cd465612336cd8298ca Signed-off-by: Elyes HAOUAS <ehaouas@noos.fr> Reviewed-on: https://review.coreboot.org/c/coreboot/+/46186 Tested-by: build bot (Jenkins) <no-reply@coreboot.org> Reviewed-by: Michael Niewöhner <foss@mniewoehner.de>
Diffstat (limited to 'src')
-rw-r--r--src/mainboard/intel/wtm2/acpi/thermal.asl44
1 files changed, 22 insertions, 22 deletions
diff --git a/src/mainboard/intel/wtm2/acpi/thermal.asl b/src/mainboard/intel/wtm2/acpi/thermal.asl
index cb56e97ad3..fe3961ef29 100644
--- a/src/mainboard/intel/wtm2/acpi/thermal.asl
+++ b/src/mainboard/intel/wtm2/acpi/thermal.asl
@@ -22,10 +22,10 @@ Scope (\_TZ)
// Convert from Degrees C to 1/10 Kelvin for ACPI
Method (CTOK, 1) {
// 10th of Degrees C
- Multiply (Arg0, 10, Local0)
+ Local0 = Arg0 * 10
// Convert to Kelvin
- Add (Local0, 2732, Local0)
+ Local0 += 2732
Return (Local0)
}
@@ -54,7 +54,7 @@ Scope (\_TZ)
}
Method (_AC0) {
- If (LLessEqual (\FLVL, 0)) {
+ If (\FLVL <= 0) {
Return (CTOK (FAN0_THRESHOLD_OFF))
} Else {
Return (CTOK (FAN0_THRESHOLD_ON))
@@ -62,7 +62,7 @@ Scope (\_TZ)
}
Method (_AC1) {
- If (LLessEqual (\FLVL, 1)) {
+ If (\FLVL <= 1) {
Return (CTOK (FAN1_THRESHOLD_OFF))
} Else {
Return (CTOK (FAN1_THRESHOLD_ON))
@@ -70,7 +70,7 @@ Scope (\_TZ)
}
Method (_AC2) {
- If (LLessEqual (\FLVL, 2)) {
+ If (\FLVL <= 2) {
Return (CTOK (FAN2_THRESHOLD_OFF))
} Else {
Return (CTOK (FAN2_THRESHOLD_ON))
@@ -78,7 +78,7 @@ Scope (\_TZ)
}
Method (_AC3) {
- If (LLessEqual (\FLVL, 3)) {
+ If (\FLVL <= 3) {
Return (CTOK (FAN3_THRESHOLD_OFF))
} Else {
Return (CTOK (FAN3_THRESHOLD_ON))
@@ -86,7 +86,7 @@ Scope (\_TZ)
}
Method (_AC4) {
- If (LLessEqual (\FLVL, 4)) {
+ If (\FLVL <= 4) {
Return (CTOK (FAN4_THRESHOLD_OFF))
} Else {
Return (CTOK (FAN4_THRESHOLD_ON))
@@ -102,18 +102,18 @@ Scope (\_TZ)
PowerResource (FNP0, 0, 0)
{
Method (_STA) {
- If (LLessEqual (\FLVL, 0)) {
+ If (\FLVL <= 0) {
Return (One)
} Else {
Return (Zero)
}
}
Method (_ON) {
- Store (0, \FLVL)
+ \FLVL = 0
Notify (\_TZ.THRM, 0x81)
}
Method (_OFF) {
- Store (1, \FLVL)
+ \FLVL = 1
Notify (\_TZ.THRM, 0x81)
}
}
@@ -121,18 +121,18 @@ Scope (\_TZ)
PowerResource (FNP1, 0, 0)
{
Method (_STA) {
- If (LLessEqual (\FLVL, 1)) {
+ If (\FLVL <= 1) {
Return (One)
} Else {
Return (Zero)
}
}
Method (_ON) {
- Store (1, \FLVL)
+ \FLVL = 1
Notify (\_TZ.THRM, 0x81)
}
Method (_OFF) {
- Store (2, \FLVL)
+ \FLVL = 2
Notify (\_TZ.THRM, 0x81)
}
}
@@ -140,18 +140,18 @@ Scope (\_TZ)
PowerResource (FNP2, 0, 0)
{
Method (_STA) {
- If (LLessEqual (\FLVL, 2)) {
+ If (\FLVL <= 2) {
Return (One)
} Else {
Return (Zero)
}
}
Method (_ON) {
- Store (2, \FLVL)
+ \FLVL = 2
Notify (\_TZ.THRM, 0x81)
}
Method (_OFF) {
- Store (3, \FLVL)
+ \FLVL = 3
Notify (\_TZ.THRM, 0x81)
}
}
@@ -159,18 +159,18 @@ Scope (\_TZ)
PowerResource (FNP3, 0, 0)
{
Method (_STA) {
- If (LLessEqual (\FLVL, 3)) {
+ If (\FLVL <= 3) {
Return (One)
} Else {
Return (Zero)
}
}
Method (_ON) {
- Store (3, \FLVL)
+ \FLVL = 3
Notify (\_TZ.THRM, 0x81)
}
Method (_OFF) {
- Store (4, \FLVL)
+ \FLVL = 4
Notify (\_TZ.THRM, 0x81)
}
}
@@ -178,18 +178,18 @@ Scope (\_TZ)
PowerResource (FNP4, 0, 0)
{
Method (_STA) {
- If (LLessEqual (\FLVL, 4)) {
+ If (\FLVL <= 4) {
Return (One)
} Else {
Return (Zero)
}
}
Method (_ON) {
- Store (4, \FLVL)
+ \FLVL = 4
Notify (\_TZ.THRM, 0x81)
}
Method (_OFF) {
- Store (4, \FLVL)
+ \FLVL = 4
Notify (\_TZ.THRM, 0x81)
}
}