diff options
author | Stefan Reinauer <reinauer@chromium.org> | 2012-05-23 14:16:47 -0700 |
---|---|---|
committer | Patrick Georgi <patrick@georgi-clan.de> | 2012-05-29 11:27:42 +0200 |
commit | 88fc0b9e8da89cd41350ca0ac54297f2ebf3bf10 (patch) | |
tree | b23d1314091eae2aa7d562e338011be4ca3f5778 /src | |
parent | 6e901fd3d267fafe97bb8404702919ce5e21a0e1 (diff) |
Sandybridge: Remove remnants of FDT support from MRC cache code
Originally, ChromeBooks would get the offset of the MRC cache
from an entry in the u-boot device tree. Not everyone wants to
use u-boot on Sandybridge systems, however.
Since the new code (based on Kconfig) is now fully working, we
can drop the u-boot device tree remnants.
Change-Id: I4e012ea981f16dce9a4d155254facd29874b28ef
Signed-off-by: Stefan Reinauer <reinauer@google.com>
Reviewed-on: http://review.coreboot.org/1051
Tested-by: build bot (Jenkins)
Reviewed-by: Patrick Georgi <patrick@georgi-clan.de>
Diffstat (limited to 'src')
-rw-r--r-- | src/northbridge/intel/sandybridge/mrccache.c | 80 |
1 files changed, 11 insertions, 69 deletions
diff --git a/src/northbridge/intel/sandybridge/mrccache.c b/src/northbridge/intel/sandybridge/mrccache.c index aad2b9104f..d774ff0988 100644 --- a/src/northbridge/intel/sandybridge/mrccache.c +++ b/src/northbridge/intel/sandybridge/mrccache.c @@ -28,19 +28,6 @@ #include "sandybridge.h" #include <spi.h> #include <spi_flash.h> -/* Using the FDT FMAP for finding the MRC cache area requires including FDT - * support in coreboot, which we would like to avoid. There are a number of - * options: - * - Have each mainboard Kconfig supply a hard-coded offset - * - For ChromeOS devices: implement native FMAP - * - For non-ChromeOS devices: use CBFS - * For now let's leave this code in here until the issue is sorted out in - * a way that works for everyone. - */ -#undef USE_FDT_FMAP_FOR_MRC_CACHE -#ifdef USE_FDT_FMAP_FOR_MRC_CACHE -#include <fdt/libfdt.h> -#endif struct mrc_data_container *next_mrc_block(struct mrc_data_container *mrc_cache) { @@ -61,64 +48,19 @@ int is_mrc_cache(struct mrc_data_container *mrc_cache) return (!!mrc_cache) && (mrc_cache->mrc_signature == MRC_DATA_SIGNATURE); } +/* Right now, the offsets for the MRC cache area are hard-coded in the + * northbridge Kconfig. In order to make this more flexible, there are + * a number of options: + * - Have each mainboard Kconfig supply a hard-coded offset + * - For ChromeOS devices: implement native FMAP + * - For non-ChromeOS devices: use CBFS + */ u32 get_mrc_cache_region(struct mrc_data_container **mrc_region_ptr) { - u8 *mrc_region; - u32 region_size; -#ifdef USE_FDT_FMAP_FOR_MRC_CACHE - u32 *data; - const struct fdt_header *fdt_header; - const struct fdt_property *fdtp; - int offset, len; - const char *compatible = "chromeos,flashmap"; - const char *subnode = "rw-mrc-cache"; - const char *property = "reg"; - u64 flashrom_base = 0; - - fdt_header = cbfs_find_file(CONFIG_FDT_FILE_NAME, CBFS_TYPE_FDT); - - if (!fdt_header) { - printk(BIOS_ERR, "%s: no FDT found!\n", __func__); - return 0; - } - - offset = fdt_node_offset_by_compatible(fdt_header, 0, compatible); - if (offset < 0) { - printk(BIOS_ERR, "%s: no %s node found!\n", - __func__, compatible); - return 0; - } - - if (fdt_get_base_addr(fdt_header, offset, &flashrom_base) < 0) { - printk(BIOS_ERR, "%s: no base address in node name!\n", - __func__); - return 0; - } - - offset = fdt_subnode_offset(fdt_header, offset, subnode); - if (offset < 0) { - printk(BIOS_ERR, "%s: no %s found!\n", __func__, subnode); - return 0; - } - - fdtp = fdt_get_property(fdt_header, offset, property, &len); - if (!fdtp || (len != 8)) { - printk(BIOS_ERR, "%s: property %s at %p, len %d!\n", - __func__, property, fdtp, len); - return 0; - } - - data = (u32 *)fdtp->data; - - // Calculate actual address of the MRC cache in memory - region_size = fdt32_to_cpu(data[1]); - mrc_region = (u8*)((unsigned long)flashrom_base + fdt32_to_cpu(data[0])); -#else - region_size = CONFIG_MRC_CACHE_SIZE; - mrc_region = (u8*)(CONFIG_MRC_CACHE_BASE + CONFIG_MRC_CACHE_LOCATION); -#endif - *mrc_region_ptr = (struct mrc_data_container *)mrc_region; + u32 region_size = CONFIG_MRC_CACHE_SIZE; + *mrc_region_ptr = (struct mrc_data_container *) + (CONFIG_MRC_CACHE_BASE + CONFIG_MRC_CACHE_LOCATION); return region_size; } @@ -182,7 +124,7 @@ struct mrc_data_container *find_current_mrc_cache(void) entry_id++; mrc_cache = mrc_next; mrc_next = next_mrc_block(mrc_cache); - /* Stay in the mrcdata region defined in fdt */ + /* Stay in the mrc data region */ if ((void*)mrc_next >= (void*)(mrc_region + region_size)) break; } |