diff options
author | Sumeet Pawnikar <sumeet.r.pawnikar@intel.com> | 2019-11-04 14:31:06 +0530 |
---|---|---|
committer | Shelley Chen <shchen@google.com> | 2019-11-05 19:14:44 +0000 |
commit | 6a657c26462f9c5896e504cd4027e58bc6db7d86 (patch) | |
tree | 8edb0da84dfe2f03a65c6d809a699dabd002f46c /src/soc/intel/icelake | |
parent | 007af4251fe83326d581d158910ecff12059dbfe (diff) |
mb/google/hatch/variants/helios: Update TSR3 sensor thresholds
Update thermal threshold settings for TSR3 sensor. There is an issue
fan is always running, even during system idle state. This change
fixes this issue and fan starts only when it breaches the temperature
threshold.
BRANCH=None
BUG=b:143861559
TEST=Built and tested on Helios system
Change-Id: Ia417f8c51442005cc8c2251c188cebc197e0a773
Signed-off-by: Sumeet Pawnikar <sumeet.r.pawnikar@intel.com>
Reviewed-on: https://review.coreboot.org/c/coreboot/+/36609
Reviewed-by: Duncan Laurie <dlaurie@chromium.org>
Reviewed-by: Shelley Chen <shchen@google.com>
Reviewed-by: Furquan Shaikh <furquan@google.com>
Tested-by: build bot (Jenkins) <no-reply@coreboot.org>
Diffstat (limited to 'src/soc/intel/icelake')
0 files changed, 0 insertions, 0 deletions