summaryrefslogtreecommitdiff
path: root/src/soc/amd/common/block
diff options
context:
space:
mode:
authorFelix Held <felix-coreboot@felixheld.de>2024-01-17 22:00:13 +0100
committerFelix Held <felix-coreboot@felixheld.de>2024-02-01 11:36:05 +0000
commit5881f8ae3658bf3a4d5bf13a6b9c4c092c08a997 (patch)
tree569e79c038f543f9e483a7d312787acfa940cc19 /src/soc/amd/common/block
parent8cfb4dc489ad30476b4c6ae57636e7a1e25398b0 (diff)
soc/amd/common,genoa_poc/domain: rework check for 1st domain
Previously the code checked if the first downstream bus of the domain was bus 0 in segment group 0 to only run certain code for the first domain. Instead check if the domain number is 0 which should make the code a bit easier to understand. TEST=add_opensil_memmap still gets called exactly once on Onyx Signed-off-by: Felix Held <felix-coreboot@felixheld.de> Change-Id: Id8cc0078843e5e0361a53ba897cde508cee16aad Reviewed-on: https://review.coreboot.org/c/coreboot/+/79996 Tested-by: build bot (Jenkins) <no-reply@coreboot.org> Reviewed-by: Arthur Heymans <arthur@aheymans.xyz>
Diffstat (limited to 'src/soc/amd/common/block')
-rw-r--r--src/soc/amd/common/block/data_fabric/domain.c2
1 files changed, 1 insertions, 1 deletions
diff --git a/src/soc/amd/common/block/data_fabric/domain.c b/src/soc/amd/common/block/data_fabric/domain.c
index f17346fedf..7bcc01bf93 100644
--- a/src/soc/amd/common/block/data_fabric/domain.c
+++ b/src/soc/amd/common/block/data_fabric/domain.c
@@ -254,7 +254,7 @@ void amd_pci_domain_fill_ssdt(const struct device *domain)
acpigen_resource_producer_bus_number(domain->downstream->secondary,
domain->downstream->max_subordinate);
- if (domain->downstream->secondary == 0 && domain->downstream->segment_group == 0) {
+ if (domain->path.domain.domain == 0) {
/* ACPI 6.4.2.5 I/O Port Descriptor */
acpigen_write_io16(PCI_IO_CONFIG_INDEX, PCI_IO_CONFIG_LAST_PORT, 1,
PCI_IO_CONFIG_PORT_COUNT, 1);