diff options
author | Elyes HAOUAS <ehaouas@noos.fr> | 2019-10-25 10:53:20 +0200 |
---|---|---|
committer | Martin Roth <martinroth@google.com> | 2019-11-29 19:23:05 +0000 |
commit | 01787608670adec26fcea48173e18395e51c790e (patch) | |
tree | 6a60df15f88244034578f80e92aa32725539fd53 /src/northbridge | |
parent | 179da7fb5cff3c9034dc3203086c84342560c600 (diff) |
{northbridge,soc,southbridge}: Don't use both of _ADR and _HID
ACPI Version 6.3 Section 6.1: "A device object must contain either an _HID
object or an _ADR object, but should not contain both."
Change-Id: Ifb777c09aeef09a6a4cbee254b081519f5b6c457
Signed-off-by: Elyes HAOUAS <ehaouas@noos.fr>
Reviewed-on: https://review.coreboot.org/c/coreboot/+/36318
Tested-by: build bot (Jenkins) <no-reply@coreboot.org>
Reviewed-by: Martin Roth <martinroth@google.com>
Diffstat (limited to 'src/northbridge')
6 files changed, 6 insertions, 8 deletions
diff --git a/src/northbridge/amd/agesa/family14/acpi/northbridge.asl b/src/northbridge/amd/agesa/family14/acpi/northbridge.asl index 06199a1b07..fad157da29 100644 --- a/src/northbridge/amd/agesa/family14/acpi/northbridge.asl +++ b/src/northbridge/amd/agesa/family14/acpi/northbridge.asl @@ -16,7 +16,7 @@ /* Note: Only need HID on Primary Bus */ External (TOM1) External (TOM2) -Name(_HID, EISAID("PNP0A08")) /* PCI Express Root Bridge */ +/* Name(_HID, EISAID("PNP0A08")) // PCI Express Root Bridge */ Name(_CID, EISAID("PNP0A03")) /* PCI Root Bridge */ Name(_ADR, 0x00180000) /* Dev# = BSP Dev#, Func# = 0 */ @@ -125,7 +125,6 @@ Device(PE23) { /* Northbridge function 3 */ Device(NBF3) { - Name(_ADR, 0x00180003) /* k10temp thermal zone */ #include "thermal_mixin.asl" diff --git a/src/northbridge/amd/agesa/family15tn/acpi/northbridge.asl b/src/northbridge/amd/agesa/family15tn/acpi/northbridge.asl index 9a1fa9ed88..96c2d8bfac 100644 --- a/src/northbridge/amd/agesa/family15tn/acpi/northbridge.asl +++ b/src/northbridge/amd/agesa/family15tn/acpi/northbridge.asl @@ -16,7 +16,7 @@ /* Note: Only need HID on Primary Bus */ External (TOM1) External (TOM2) -Name(_HID, EISAID("PNP0A03")) /* PCI Express Root Bridge */ +/* Name(_HID, EISAID("PNP0A03")) // PCI Express Root Bridge */ Name(_ADR, 0x00180000) /* Dev# = BSP Dev#, Func# = 0 */ /* Describe the Northbridge devices */ diff --git a/src/northbridge/amd/agesa/family16kb/acpi/northbridge.asl b/src/northbridge/amd/agesa/family16kb/acpi/northbridge.asl index f74b31a080..a7e8307349 100644 --- a/src/northbridge/amd/agesa/family16kb/acpi/northbridge.asl +++ b/src/northbridge/amd/agesa/family16kb/acpi/northbridge.asl @@ -16,7 +16,7 @@ /* Note: Only need HID on Primary Bus */ External (TOM1) External (TOM2) -Name(_HID, EISAID("PNP0A08")) /* PCI Express Root Bridge */ +/* Name(_HID, EISAID("PNP0A08")) // PCI Express Root Bridge */ Name(_CID, EISAID("PNP0A03")) /* PCI Root Bridge */ Name(_ADR, 0x00180000) /* Dev# = BSP Dev#, Func# = 0 */ diff --git a/src/northbridge/amd/pi/00630F01/acpi/northbridge.asl b/src/northbridge/amd/pi/00630F01/acpi/northbridge.asl index c2b3aac4c5..de47bc2151 100644 --- a/src/northbridge/amd/pi/00630F01/acpi/northbridge.asl +++ b/src/northbridge/amd/pi/00630F01/acpi/northbridge.asl @@ -16,7 +16,7 @@ /* Note: Only need HID on Primary Bus */ External (TOM1) External (TOM2) -Name(_HID, EISAID("PNP0A03")) /* PCI Express Root Bridge */ +/* Name(_HID, EISAID("PNP0A03")) // PCI Express Root Bridge */ Name(_ADR, 0x00180000) /* Dev# = BSP Dev#, Func# = 0 */ /* Describe the Northbridge devices */ diff --git a/src/northbridge/amd/pi/00660F01/acpi/northbridge.asl b/src/northbridge/amd/pi/00660F01/acpi/northbridge.asl index d54f985e90..4a48aaf401 100644 --- a/src/northbridge/amd/pi/00660F01/acpi/northbridge.asl +++ b/src/northbridge/amd/pi/00660F01/acpi/northbridge.asl @@ -16,7 +16,7 @@ /* Note: Only need HID on Primary Bus */ External (TOM1) External (TOM2) -Name(_HID, EISAID("PNP0A08")) /* PCI Express Root Bridge */ +/* Name(_HID, EISAID("PNP0A08")) // PCI Express Root Bridge */ Name(_CID, EISAID("PNP0A03")) /* PCI Root Bridge */ Name(_ADR, 0x00180000) /* Dev# = BSP Dev#, Func# = 0 */ diff --git a/src/northbridge/amd/pi/00730F01/acpi/northbridge.asl b/src/northbridge/amd/pi/00730F01/acpi/northbridge.asl index f74b31a080..b317ccf1ea 100644 --- a/src/northbridge/amd/pi/00730F01/acpi/northbridge.asl +++ b/src/northbridge/amd/pi/00730F01/acpi/northbridge.asl @@ -16,10 +16,9 @@ /* Note: Only need HID on Primary Bus */ External (TOM1) External (TOM2) -Name(_HID, EISAID("PNP0A08")) /* PCI Express Root Bridge */ +/* Name(_HID, EISAID("PNP0A08")) // PCI Express Root Bridge */ Name(_CID, EISAID("PNP0A03")) /* PCI Root Bridge */ Name(_ADR, 0x00180000) /* Dev# = BSP Dev#, Func# = 0 */ - /* Describe the Northbridge devices */ Method(_BBN, 0, NotSerialized) /* Bus number = 0 */ |