summaryrefslogtreecommitdiff
path: root/src/northbridge
diff options
context:
space:
mode:
authorSven Schnelle <svens@stackframe.org>2012-06-17 14:23:35 +0200
committerSven Schnelle <svens@stackframe.org>2012-06-18 09:03:35 +0200
commit1a7a7e610e0fbc54fcc802bedbb31673dffff449 (patch)
tree89b38df2cd6c713ca41948ab03f58d99d3588b9f /src/northbridge
parentec6f043c253355483bd065c39adc91bad2647ee9 (diff)
i5000: enforce hard reset
Not doing a hard reset leaves the BOFL0 register cleared, which prevents the BSP selection from working. To make sure we start with known values, use the SPAD0 register for soft reset detection. If there's a value other than 0, do a hard reset. Change-Id: I390e3208084cfd32d73cce439ddf2bc9d4436a62 Signed-off-by: Sven Schnelle <svens@stackframe.org> Reviewed-on: http://review.coreboot.org/1103 Tested-by: build bot (Jenkins)
Diffstat (limited to 'src/northbridge')
-rw-r--r--src/northbridge/intel/i5000/halt_second_bsp.S31
1 files changed, 30 insertions, 1 deletions
diff --git a/src/northbridge/intel/i5000/halt_second_bsp.S b/src/northbridge/intel/i5000/halt_second_bsp.S
index a1a1b156db..2dc533ac53 100644
--- a/src/northbridge/intel/i5000/halt_second_bsp.S
+++ b/src/northbridge/intel/i5000/halt_second_bsp.S
@@ -2,6 +2,26 @@
movl %eax, %ebp
+ /* check if SPAD0 is cleared. If yes, it means this was a hard reset */
+ movl $0x800080d0, %eax
+ movw $0xcf8, %dx
+ outl %eax, %dx
+
+ addw $4, %dx
+ inl %dx, %eax
+ cmp $0, %eax
+ je no_reset
+
+ /* perform hard reset */
+ movw $0xcf9, %dx
+ movw $0x06, %ax
+ outw %ax, %dx
+
+loop0: hlt
+ jmp loop
+
+no_reset:
+
/* Read the semaphore register of i5000 (BOFL0).
If it returns zero, it means there was already
another read by another CPU */
@@ -25,5 +45,14 @@
loop: hlt
jmp loop
-1: /* Restore BIST */
+1: /* set magic value for soft reset detection */
+ movl $0x800080d0, %eax
+ movw $0xcf8, %dx
+ outl %eax, %dx
+
+ addw $4, %dx
+ movl $0x12345678, %eax
+ outl %eax, %dx
+
+ /* Restore BIST */
mov %ebp, %eax