summaryrefslogtreecommitdiff
path: root/src/mainboard/prodrive/hermes/variants
diff options
context:
space:
mode:
authorPatrick Rudolph <patrick.rudolph@9elements.com>2020-11-05 11:30:16 +0100
committerPatrick Rudolph <siro@das-labor.org>2020-12-14 20:10:59 +0000
commit4ce5b632947d3a2ea06d3e58a8a197cee35115ce (patch)
tree260d65c9be51144dfe9c7229c318a47f916c2035 /src/mainboard/prodrive/hermes/variants
parentd9d711c7f5dda34cdad9f8ee73dc8fead86fc6eb (diff)
mb/prodrive/hermes: Update PCIe slots in devicetree
* Drop PcieRpSlotImplemented on internal slots * Add PCIe port 15 that connected to CNVi/M.2 E Change-Id: Iaa05affa760b447fc1725e674b12366684a63720 Signed-off-by: Patrick Rudolph <patrick.rudolph@9elements.com> Reviewed-on: https://review.coreboot.org/c/coreboot/+/47239 Tested-by: build bot (Jenkins) <no-reply@coreboot.org> Reviewed-by: Angel Pons <th3fanbus@gmail.com> Reviewed-by: Christian Walter <christian.walter@9elements.com> Reviewed-by: Arthur Heymans <arthur@aheymans.xyz>
Diffstat (limited to 'src/mainboard/prodrive/hermes/variants')
-rw-r--r--src/mainboard/prodrive/hermes/variants/baseboard/overridetree.cb27
1 files changed, 9 insertions, 18 deletions
diff --git a/src/mainboard/prodrive/hermes/variants/baseboard/overridetree.cb b/src/mainboard/prodrive/hermes/variants/baseboard/overridetree.cb
index 025510e7ce..b543a78c5c 100644
--- a/src/mainboard/prodrive/hermes/variants/baseboard/overridetree.cb
+++ b/src/mainboard/prodrive/hermes/variants/baseboard/overridetree.cb
@@ -185,30 +185,21 @@ chip soc/intel/cannonlake
smbios_slot_desc "SlotTypePciExpressGen3X16" "SlotLengthOther" "SLOT3" "SlotDataBusWidth4X"
register "PcieRpSlotImplemented[0]" = "1"
end
- device pci 1c.4 on # PCIe root port 5 (PHY 3)
- register "PcieRpSlotImplemented[4]" = "1"
- end
- device pci 1c.5 on # PCIe root port 6 (PHY 4)
- register "PcieRpSlotImplemented[5]" = "1"
- end
- device pci 1c.6 on # PCIe root port 7 (PHY 2)
- register "PcieRpSlotImplemented[6]" = "1"
- end
- device pci 1c.7 on # PCIe root port 8 (PHY 1)
- register "PcieRpSlotImplemented[7]" = "1"
- end
+ device pci 1c.4 on end # PCIe root port 5 (PHY 3)
+ device pci 1c.5 on end # PCIe root port 6 (PHY 4)
+ device pci 1c.6 on end # PCIe root port 7 (PHY 2)
+ device pci 1c.7 on end # PCIe root port 8 (PHY 1)
device pci 1d.0 on # PCIe root port 9 (M2 M)
smbios_slot_desc "SlotTypePciExpressGen3X16" "SlotLengthOther" "M2 M" "SlotDataBusWidth4X"
register "PcieRpSlotImplemented[8]" = "1"
end
- device pci 1d.5 on # PCIe root port 14 (PHY 0)
- register "PcieRpSlotImplemented[13]" = "1"
- end
- device pci 1d.6 on # PCIe root port 15 (BMC)
- register "PcieRpSlotImplemented[14]" = "1"
+ device pci 1d.5 on end # PCIe root port 14 (PHY 0)
+ device pci 1d.6 on end # PCIe root port 15 (BMC)
+ device pci 1d.7 on # PCIe root port 16 (M.2 E/CNVi)
+ # Disabled when CNVi is present
+ register "PcieRpSlotImplemented[15]" = "1"
end
-
device pci 1e.0 on end # UART #0
device pci 1e.1 on end # UART #1
device pci 1e.2 off end # GSPI #0