summaryrefslogtreecommitdiff
path: root/src/mainboard/lenovo/x201
diff options
context:
space:
mode:
authorDennis Wassenberg <dennis.wassenberg@secunet.com>2014-10-14 17:29:36 +0200
committerNico Huber <nico.h@gmx.de>2014-10-24 10:38:26 +0200
commit498c32a6e8d06e3989cb83def86952e9301b84ee (patch)
tree97224aef583ebf521ce5d8e1d41c6f84185bac88 /src/mainboard/lenovo/x201
parent7d6b0afdf5dee7e0149c7a62217ee3cdcc9b53b8 (diff)
siemens/sitemp_g1p1: Fix serial output for simo board
The simo board with console output at UART port 1 (COM2) will not produce any output if CONFIG_UART_FOR_CONSOLE=1 is set correctly. Commit f29200240e428761827ab8d179fa23068bfa9d59 (superio/ite/*: Factor out generic romstage component) will only and always activate UART port 0 unregarded to CONFIG_UART_FOR_CONSOLE value. Now the UART port which was selected by CONFIG_UART_FOR_CONSOLE will be enabled and used for console output Change-Id: Ibbd2b5115b1ed4763962ba32fc9c19431a906c78 Signed-off-by: Dennis Wassenberg <dennis.wassenberg@secunet.com> Reviewed-on: http://review.coreboot.org/7060 Tested-by: build bot (Jenkins) Reviewed-by: Nico Huber <nico.h@gmx.de>
Diffstat (limited to 'src/mainboard/lenovo/x201')
0 files changed, 0 insertions, 0 deletions