diff options
author | Elyes HAOUAS <ehaouas@noos.fr> | 2020-10-08 09:39:22 +0200 |
---|---|---|
committer | Michael Niewöhner <foss@mniewoehner.de> | 2021-02-10 17:46:38 +0000 |
commit | b4b4fa5b2fad4d5dfbfd8cd7b0d3d17b686fb0e1 (patch) | |
tree | a79ea2258eeb366bc0c4ab058a5c42070b9c71d4 /src/mainboard/intel | |
parent | e166cb38bf8f01944bff435b5fef79f9f0b7a50d (diff) |
mb/intel/wtm2: Convert to ASL 2.0 syntax
Generated 'build/dsdt.dsl' files are same.
Change-Id: Id68623cfb57e889e60d66cd465612336cd8298ca
Signed-off-by: Elyes HAOUAS <ehaouas@noos.fr>
Reviewed-on: https://review.coreboot.org/c/coreboot/+/46186
Tested-by: build bot (Jenkins) <no-reply@coreboot.org>
Reviewed-by: Michael Niewöhner <foss@mniewoehner.de>
Diffstat (limited to 'src/mainboard/intel')
-rw-r--r-- | src/mainboard/intel/wtm2/acpi/thermal.asl | 44 |
1 files changed, 22 insertions, 22 deletions
diff --git a/src/mainboard/intel/wtm2/acpi/thermal.asl b/src/mainboard/intel/wtm2/acpi/thermal.asl index cb56e97ad3..fe3961ef29 100644 --- a/src/mainboard/intel/wtm2/acpi/thermal.asl +++ b/src/mainboard/intel/wtm2/acpi/thermal.asl @@ -22,10 +22,10 @@ Scope (\_TZ) // Convert from Degrees C to 1/10 Kelvin for ACPI Method (CTOK, 1) { // 10th of Degrees C - Multiply (Arg0, 10, Local0) + Local0 = Arg0 * 10 // Convert to Kelvin - Add (Local0, 2732, Local0) + Local0 += 2732 Return (Local0) } @@ -54,7 +54,7 @@ Scope (\_TZ) } Method (_AC0) { - If (LLessEqual (\FLVL, 0)) { + If (\FLVL <= 0) { Return (CTOK (FAN0_THRESHOLD_OFF)) } Else { Return (CTOK (FAN0_THRESHOLD_ON)) @@ -62,7 +62,7 @@ Scope (\_TZ) } Method (_AC1) { - If (LLessEqual (\FLVL, 1)) { + If (\FLVL <= 1) { Return (CTOK (FAN1_THRESHOLD_OFF)) } Else { Return (CTOK (FAN1_THRESHOLD_ON)) @@ -70,7 +70,7 @@ Scope (\_TZ) } Method (_AC2) { - If (LLessEqual (\FLVL, 2)) { + If (\FLVL <= 2) { Return (CTOK (FAN2_THRESHOLD_OFF)) } Else { Return (CTOK (FAN2_THRESHOLD_ON)) @@ -78,7 +78,7 @@ Scope (\_TZ) } Method (_AC3) { - If (LLessEqual (\FLVL, 3)) { + If (\FLVL <= 3) { Return (CTOK (FAN3_THRESHOLD_OFF)) } Else { Return (CTOK (FAN3_THRESHOLD_ON)) @@ -86,7 +86,7 @@ Scope (\_TZ) } Method (_AC4) { - If (LLessEqual (\FLVL, 4)) { + If (\FLVL <= 4) { Return (CTOK (FAN4_THRESHOLD_OFF)) } Else { Return (CTOK (FAN4_THRESHOLD_ON)) @@ -102,18 +102,18 @@ Scope (\_TZ) PowerResource (FNP0, 0, 0) { Method (_STA) { - If (LLessEqual (\FLVL, 0)) { + If (\FLVL <= 0) { Return (One) } Else { Return (Zero) } } Method (_ON) { - Store (0, \FLVL) + \FLVL = 0 Notify (\_TZ.THRM, 0x81) } Method (_OFF) { - Store (1, \FLVL) + \FLVL = 1 Notify (\_TZ.THRM, 0x81) } } @@ -121,18 +121,18 @@ Scope (\_TZ) PowerResource (FNP1, 0, 0) { Method (_STA) { - If (LLessEqual (\FLVL, 1)) { + If (\FLVL <= 1) { Return (One) } Else { Return (Zero) } } Method (_ON) { - Store (1, \FLVL) + \FLVL = 1 Notify (\_TZ.THRM, 0x81) } Method (_OFF) { - Store (2, \FLVL) + \FLVL = 2 Notify (\_TZ.THRM, 0x81) } } @@ -140,18 +140,18 @@ Scope (\_TZ) PowerResource (FNP2, 0, 0) { Method (_STA) { - If (LLessEqual (\FLVL, 2)) { + If (\FLVL <= 2) { Return (One) } Else { Return (Zero) } } Method (_ON) { - Store (2, \FLVL) + \FLVL = 2 Notify (\_TZ.THRM, 0x81) } Method (_OFF) { - Store (3, \FLVL) + \FLVL = 3 Notify (\_TZ.THRM, 0x81) } } @@ -159,18 +159,18 @@ Scope (\_TZ) PowerResource (FNP3, 0, 0) { Method (_STA) { - If (LLessEqual (\FLVL, 3)) { + If (\FLVL <= 3) { Return (One) } Else { Return (Zero) } } Method (_ON) { - Store (3, \FLVL) + \FLVL = 3 Notify (\_TZ.THRM, 0x81) } Method (_OFF) { - Store (4, \FLVL) + \FLVL = 4 Notify (\_TZ.THRM, 0x81) } } @@ -178,18 +178,18 @@ Scope (\_TZ) PowerResource (FNP4, 0, 0) { Method (_STA) { - If (LLessEqual (\FLVL, 4)) { + If (\FLVL <= 4) { Return (One) } Else { Return (Zero) } } Method (_ON) { - Store (4, \FLVL) + \FLVL = 4 Notify (\_TZ.THRM, 0x81) } Method (_OFF) { - Store (4, \FLVL) + \FLVL = 4 Notify (\_TZ.THRM, 0x81) } } |