authorMario Scheithauer <mario.scheithauer@siemens.com>2022-04-27 11:26:56 +0200
committerFelix Held <felix-coreboot@felixheld.de>2022-05-21 17:41:16 +0000
commit5b3ccc253f78996216207ae3d5f77072f7a04621 (patch)
tree5a595abd510a9dd013fd4d5919857f782bca6e2f /src/mainboard/google
parentdccdaceb494fdb0466a1c46b68df3642280f587f (diff)
mb/siemens/mc_ehl2: Invert PHY IRQ from falling edge to rising edge
There are three external Marvell PHY 88E1512 on this mainboard. The PHY IRQ comes with a falling edge but the EHL MAC side needs a rising edge signal. For that reason, we need an inversion of the IRQ polarity. Change-Id: Id3caf582b4434b046779f5733e6ad9b57528ce35 Signed-off-by: Mario Scheithauer <mario.scheithauer@siemens.com> Reviewed-on: https://review.coreboot.org/c/coreboot/+/63889 Tested-by: build bot (Jenkins) <no-reply@coreboot.org> Reviewed-by: Werner Zeh <werner.zeh@siemens.com>