summaryrefslogtreecommitdiff
path: root/src/mainboard/google/chell
diff options
context:
space:
mode:
authorWerner Zeh <werner.zeh@siemens.com>2017-06-29 08:56:45 +0200
committerWerner Zeh <werner.zeh@siemens.com>2017-06-30 16:57:21 +0000
commitc439109359b91e597c06e9532f812931ed7fd0a2 (patch)
tree69902873f54e8bc985e35ff29037a1eaf69ba474 /src/mainboard/google/chell
parent6e6261e89344ff25dc3beb0b8abb753ff2347624 (diff)
mb/siemens/mc_bdx1: Set up RTC backup mode to primary cell
The used RTC6110SA has issues to enter backup mode when the power supply decreases too slow when the mainboard is turned off. Switch to backup mode "primary cell" to make sure backup mode will be entered correctly on power-off. In addition set IOCUTEN to minimize the backup current consumption of the RTC. Change-Id: I9733aa9f2981a25f6d42279eff0c4980e5eb5a5a Signed-off-by: Werner Zeh <werner.zeh@siemens.com> Reviewed-on: https://review.coreboot.org/20413 Tested-by: build bot (Jenkins) <no-reply@coreboot.org> Reviewed-by: Martin Roth <martinroth@google.com>
Diffstat (limited to 'src/mainboard/google/chell')
0 files changed, 0 insertions, 0 deletions