summaryrefslogtreecommitdiff
path: root/src/ec/quanta
diff options
context:
space:
mode:
authorVladimir Serbinenko <phcoder@gmail.com>2013-06-07 01:34:06 +0200
committerRonald G. Minnich <rminnich@gmail.com>2013-06-12 05:29:51 +0200
commit26419285bf6643776d5ad6534db7d0422758efb2 (patch)
treeb854e11a926e555a4ade85950846b8cdea0ce56b /src/ec/quanta
parentfe50d0bcfe96210413d9c2372d3daa779892b520 (diff)
Avoid tripping overheat alarm on X201 before ME boots
Until ME boots (which takes seconds on X201) the reported temperature is 128 °C which triggers Linux overheat alarm which shuts down. Pretend temperature is 40°C until ME boots. Change-Id: Ia49fa03c6eb27f539a23711f2c8ebfde72b1dc18 Signed-off-by: Vladimir Serbinenko <phcoder@gmail.com> Reviewed-on: http://review.coreboot.org/3404 Tested-by: build bot (Jenkins) Reviewed-by: Ronald G. Minnich <rminnich@gmail.com>
Diffstat (limited to 'src/ec/quanta')
0 files changed, 0 insertions, 0 deletions