summaryrefslogtreecommitdiff
path: root/src/ec/hp/kbc1126
diff options
context:
space:
mode:
authorMario Scheithauer <mario.scheithauer@siemens.com>2023-05-09 09:49:13 +0200
committerFelix Held <felix-coreboot@felixheld.de>2023-05-11 16:48:15 +0000
commit7ad8b0987ac6f3438b209ce2c6d3bd16a5c93f21 (patch)
tree65b13a09ac51d7ed11ef961c4ad2854e22b5b29a /src/ec/hp/kbc1126
parent08706a3ad03cf9005c788451f93a4f7b5508720f (diff)
mb/siemens/mc_apl5: Set Full Reset Bit into Reset Control Register
With the introduction of a new Linux version a problem has appeared after a software initiated reset via CF9h register. The problem manifests itself in the fact that the Linux kernel does not start after the reboot. The problem is solved by setting bit 3 to 1 in Reset Control Register (I/O port CF9h). This leads to the fact that the PCH will drive SLP_S3 active low in the reset sequence. It leads to the same behavior as in commit 04ea73ee78bc ("siemens/mc_apl3: Set Full Reset Bit into Reset Control Register") explained. Change-Id: Ia8b7f997ca6234add569da751e1070144790e258 Signed-off-by: Mario Scheithauer <mario.scheithauer@siemens.com> Reviewed-on: https://review.coreboot.org/c/coreboot/+/75041 Tested-by: build bot (Jenkins) <no-reply@coreboot.org> Reviewed-by: Jan Samek <jan.samek@siemens.com> Reviewed-by: Werner Zeh <werner.zeh@siemens.com>
Diffstat (limited to 'src/ec/hp/kbc1126')
0 files changed, 0 insertions, 0 deletions