diff options
author | Subrata Banik <subrata.banik@intel.com> | 2017-11-29 16:42:10 +0530 |
---|---|---|
committer | Subrata Banik <subrata.banik@intel.com> | 2017-11-30 16:27:20 +0000 |
commit | a6802ec30f5ea4821cea7e0d953b77865e4fdd52 (patch) | |
tree | ac7cce41aa71728a8b7d7c341774be8d8af023ec /src/cpu | |
parent | 771d611f9ea6aa9b6dbf0ea0fffa5fb48e059351 (diff) |
mb/google/poppy/variants/soraka: Set PCH thermal trip point to 75 degreeC
PMC logic shuts down the thermal sensor when CPU is in a C-state and
DTS Temp <= Low Temp Threshold in case Dynamic Thermal Shutdown in
S0ix is enabled.
BUG=b:69110373
BRANCH=none
TEST=Ensure Thermal Device(B0: D20: F2) TSPM offset 0x1c[LTT (8:0)]
value is 0xFA.
Change-Id: I6246300a4376a0194950d4de277af040b10b6c1f
Signed-off-by: Subrata Banik <subrata.banik@intel.com>
Reviewed-on: https://review.coreboot.org/22628
Tested-by: build bot (Jenkins) <no-reply@coreboot.org>
Reviewed-by: Aaron Durbin <adurbin@chromium.org>
Reviewed-by: Sumeet R Pawnikar <sumeet.r.pawnikar@intel.com>
Reviewed-by: Furquan Shaikh <furquan@google.com>
Diffstat (limited to 'src/cpu')
0 files changed, 0 insertions, 0 deletions