#!/usr/bin/env python3 import cmd import time import logging import socket import sys import threading import os.path sys.path.extend([ os.path.realpath( os.path.join(os.path.dirname(os.path.join(__file__)), '..') ) ]) from enum import Enum, auto from typing import Optional from src.home.util import stringify from src.home.config import config from src.home.inverter import ( wrapper_instance as inverter, InverterMonitor, ChargingEvent, BatteryState, BatteryPowerDirection, ) def monitor_charging(event: ChargingEvent, **kwargs) -> None: msg = 'event: ' + event.name if event == ChargingEvent.AC_CURRENT_CHANGED: msg += f' (current={kwargs["current"]})' evt_logger.info(msg) def monitor_battery(state: BatteryState, v: float, load_watts: int) -> None: evt_logger.info(f'bat: {state.name}, v: {v}, load_watts: {load_watts}') def monitor_error(error: str) -> None: evt_logger.warning('error: ' + error) class InverterTestShell(cmd.Cmd): intro = 'Welcome to the test shell. Type help or ? to list commands.\n' prompt = '(test) ' file = None def do_connect_ac(self, arg): server.connect_ac() def do_disconnect_ac(self, arg): server.disconnect_ac() def do_pd_charge(self, arg): server.set_pd(BatteryPowerDirection.CHARGING) def do_pd_nothing(self, arg): server.set_pd(BatteryPowerDirection.DO_NOTHING) def do_pd_discharge(self, arg): server.set_pd(BatteryPowerDirection.DISCHARGING) class ChargerMode(Enum): NONE = auto() CHARGING = auto() class ChargerEmulator(threading.Thread): def __init__(self): super().__init__() self.setName('ChargerEmulator') self.logger = logging.getLogger('charger') self.interrupted = False self.mode = ChargerMode.NONE self.pd = None self.ac_connected = False self.mppt_connected = False def run(self): while not self.interrupted: if self.pd == BatteryPowerDirection.CHARGING\ and self.ac_connected\ and not self.mppt_connected: v = server._get_voltage() + 0.02 self.logger.info('incrementing voltage') server.set_voltage(v) time.sleep(2) def stop(self): self.interrupted = True def setmode(self, mode: ChargerMode): self.mode = mode def ac_changed(self, connected: bool): self.ac_connected = connected def mppt_changed(self, connected: bool): self.mppt_connected = connected def current_changed(self, amps): # FIXME # this method is not being called and voltage is not changing] # when current changes v = None if amps == 2: v = 49 elif amps == 10: v = 51 elif amps == 20: v = 52.5 elif amps == 30: v = 53.5 elif amps == 40: v = 54.5 if v is not None: self.logger.info(f'setting voltage {v}') server.set_voltage(v) def pd_changed(self, pd: BatteryPowerDirection): self.pd = pd class InverterEmulator(threading.Thread): def __init__(self, host: str, port: int): super().__init__() self.setName('InverterEmulatorServer') self.lock = threading.Lock() self.status = {"grid_voltage": {"unit": "V", "value": 0.0}, "grid_freq": {"unit": "Hz", "value": 0.0}, "ac_output_voltage": {"unit": "V", "value": 230.0}, "ac_output_freq": {"unit": "Hz", "value": 50.0}, "ac_output_apparent_power": {"unit": "VA", "value": 92}, "ac_output_active_power": {"unit": "Wh", "value": 30}, "output_load_percent": {"unit": "%", "value": 1}, "battery_voltage": {"unit": "V", "value": 48.4}, "battery_voltage_scc": {"unit": "V", "value": 0.0}, "battery_voltage_scc2": {"unit": "V", "value": 0.0}, "battery_discharging_current": {"unit": "A", "value": 0}, "battery_charging_current": {"unit": "A", "value": 0}, "battery_capacity": {"unit": "%", "value": 62}, "inverter_heat_sink_temp": {"unit": "°C", "value": 8}, "mppt1_charger_temp": {"unit": "°C", "value": 0}, "mppt2_charger_temp": {"unit": "°C", "value": 0}, "pv1_input_power": {"unit": "Wh", "value": 0}, "pv2_input_power": {"unit": "Wh", "value": 0}, "pv1_input_voltage": {"unit": "V", "value": 0.0}, "pv2_input_voltage": {"unit": "V", "value": 0.0}, "configuration_status": "Default", "mppt1_charger_status": "Abnormal", "mppt2_charger_status": "Abnormal", "load_connected": "Connected", "battery_power_direction": "Discharge", "dc_ac_power_direction": "DC/AC", "line_power_direction": "Do nothing", "local_parallel_id": 0} self.rated = {"ac_input_rating_voltage": {"unit": "V", "value": 230.0}, "ac_input_rating_current": {"unit": "A", "value": 21.7}, "ac_output_rating_voltage": {"unit": "V", "value": 230.0}, "ac_output_rating_freq": {"unit": "Hz", "value": 50.0}, "ac_output_rating_current": {"unit": "A", "value": 21.7}, "ac_output_rating_apparent_power": {"unit": "VA", "value": 5000}, "ac_output_rating_active_power": {"unit": "Wh", "value": 5000}, "battery_rating_voltage": {"unit": "V", "value": 48.0}, "battery_recharge_voltage": {"unit": "V", "value": 51.0}, "battery_redischarge_voltage": {"unit": "V", "value": 58.0}, "battery_under_voltage": {"unit": "V", "value": 42.0}, "battery_bulk_voltage": {"unit": "V", "value": 57.6}, "battery_float_voltage": {"unit": "V", "value": 54.0}, "battery_type": "User", "max_charging_current": {"unit": "A", "value": 60}, "max_ac_charging_current": {"unit": "A", "value": 10}, "input_voltage_range": "Appliance", "output_source_priority": "Parallel output", "charge_source_priority": "Solar-and-Utility", "parallel_max_num": 6, "machine_type": "Off-Grid-Tie", "topology": "Transformer-less", "output_model_setting": "Single module", "solar_power_priority": "Load-Battery-Utility", "mppt": "2"} self.host = host self.port = port self.interrupted = False self.logger = logging.getLogger('srv') self.sock = socket.socket(socket.AF_INET, socket.SOCK_STREAM) self.sock.setsockopt(socket.SOL_SOCKET, socket.SO_REUSEADDR, 1) self.sock.bind((self.host, self.port)) def run(self): self.sock.listen(5) while not self.interrupted: conn, address = self.sock.accept() alive = True while alive: try: buf = conn.recv(2048) message = buf.decode().strip() except OSError as exc: self.logger.error('failed to recv()') self.logger.exception(exc) alive = False try: conn.close() except: pass continue # exit the loop self.logger.log(0, f'< {message}') if message.strip() == '': continue if message == 'format json': # self.logger.info(f'got {message}') self.reply_ok(conn) elif message.startswith('exec '): command = message[5:].split() args = command[1:] command = command[0] if command == 'get-allowed-ac-charging-currents': self.reply_ok(conn, [2, 10, 20, 30, 40, 50, 60]) elif command == 'get-status': self.reply_ok(conn, self._get_status()) elif command == 'get-rated': self.reply_ok(conn, self._get_rated()) elif command == 'set-max-ac-charging-current': self.set_ac_current(args[1]) self.reply_ok(conn, 1) else: raise ValueError('unsupported command: ' + command) else: raise ValueError('unexpected request: ' + message) def reply_ok(self, connection, data=None): buf = 'ok' + '\r\n' if data: if not isinstance(data, str): data = stringify({'result': 'ok', 'data': data}) buf += data + '\r\n' buf += '\r\n' self.logger.log(0, f'> {buf.strip()}') connection.sendall(buf.encode()) def _get_status(self) -> dict: with self.lock: return self.status def _get_rated(self) -> dict: with self.lock: return self.rated def _get_voltage(self) -> float: with self.lock: return self.status['battery_voltage']['value'] def stop(self): self.interrupted = True self.sock.close() def connect_ac(self): with self.lock: self.status['grid_voltage']['value'] = 230 self.status['grid_freq']['value'] = 50 charger.ac_changed(True) def disconnect_ac(self): with self.lock: self.status['grid_voltage']['value'] = 0 self.status['grid_freq']['value'] = 0 #self.status['battery_voltage']['value'] = 48.4 # revert to initial value charger.ac_changed(False) def connect_mppt(self): with self.lock: self.status['pv1_input_power']['value'] = 1 self.status['pv1_input_voltage']['value'] = 50 self.status['mppt1_charger_status'] = 'Charging' charger.mppt_changed(True) def disconnect_mppt(self): with self.lock: self.status['pv1_input_power']['value'] = 0 self.status['pv1_input_voltage']['value'] = 0 self.status['mppt1_charger_status'] = 'Abnormal' charger.mppt_changed(False) def set_voltage(self, v: float): with self.lock: self.status['battery_voltage']['value'] = v def set_ac_current(self, amps): with self.lock: self.rated['max_ac_charging_current']['value'] = amps charger.current_changed(amps) def set_pd(self, pd: BatteryPowerDirection): if pd == BatteryPowerDirection.CHARGING: val = 'Charge' elif pd == BatteryPowerDirection.DISCHARGING: val = 'Discharge' else: val = 'Do nothing' with self.lock: self.status['battery_power_direction'] = val charger.pd_changed(pd) logger = logging.getLogger(__name__) evt_logger = logging.getLogger('evt') server: Optional[InverterEmulator] = None charger: Optional[ChargerEmulator] = None def main(): global server, charger # start fake inverterd server try: server = InverterEmulator(host=config['inverter']['host'], port=config['inverter']['port']) server.start() except OSError as e: logger.error('failed to start server') logger.exception(e) return logger.info('server started') # start charger thread charger = ChargerEmulator() charger.start() # init inverterd wrapper inverter.init(host=config['inverter']['host'], port=config['inverter']['port']) # start monitor mon = InverterMonitor() mon.set_charging_event_handler(monitor_charging) mon.set_battery_event_handler(monitor_battery) mon.set_error_handler(monitor_error) mon.start() logger.info('monitor started') try: InverterTestShell().cmdloop() server.join() mon.join() charger.join() except KeyboardInterrupt: server.stop() mon.stop() charger.stop() if __name__ == '__main__': config.load('test_inverter_monitor') main()