/* SPDX-License-Identifier: GPL-2.0-only */ // Thermal Zone External (\PPKG, MethodObj) #define HAVE_THERMALZONE Scope (\_TZ) { // Convert from Degrees C to 1/10 Kelvin for ACPI Method (CTOK, 1) { // 10th of Degrees C Local0 = Arg0 * 10 // Convert to Kelvin Local0 += 2732 Return (Local0) } ThermalZone (THRM) { Name (_TC1, 0x02) Name (_TC2, 0x05) // Thermal zone polling frequency: 10 seconds Name (_TZP, 100) // Thermal sampling period for passive cooling: 2 seconds Name (_TSP, 20) // Threshold for OS to shutdown Method (_CRT, 0, Serialized) { Return (CTOK (\TCRT)) } // Threshold for passive cooling Method (_PSV, 0, Serialized) { Return (CTOK (\TPSV)) } // Processors used for passive cooling Method (_PSL, 0, Serialized) { Return (\PPKG ()) } Method (_TMP, 0, NotSerialized) // _TMP: Temperature { Local0 = \_SB.PCI0.LPCB.EC0.CPUT If (Local0 >= 0x80) { Debug = "-----> CPU Temperature (INVALID): " Debug = Local0 Return (CTOK (0)) } Debug = "-----> CPU Temperature: " Debug = Local0 Return (CTOK (Local0)) } } ThermalZone (TZ00) { // Thermal zone polling frequency: 10 seconds Name (_TZP, 100) // Thermal sampling period for passive cooling: 2 seconds Name (_TSP, 20) // Threshold for OS to shutdown Method (_CRT, 0, Serialized) { Return (CTOK (106)) } Method (_TMP, 0, NotSerialized) // _TMP: Temperature { Local0 = \_SB.PCI0.LPCB.EC0.LOCT If (Local0 >= 0x80) { Debug = "-----> LOC Temperature (INVALID): " Debug = Local0 Return (CTOK (0)) } Debug = "-----> LOC Temperature: " Debug = Local0 Return (CTOK (Local0)) } } ThermalZone (TZ01) { // Thermal zone polling frequency: 10 seconds Name (_TZP, 100) // Thermal sampling period for passive cooling: 2 seconds Name (_TSP, 20) // Threshold for OS to shutdown Method (_CRT, 0, Serialized) { Return (CTOK (106)) } Method (_TMP, 0, NotSerialized) // _TMP: Temperature { Local0 = \_SB.PCI0.LPCB.EC0.OEMT If (Local0 >= 0x80) { Debug = "-----> OEM Temperature (INVALID): " Debug = Local0 Return (CTOK (0)) } Debug = "-----> OEM Temperature: " Debug = Local0 Return (CTOK (Local0)) } } }