/* SPDX-License-Identifier: GPL-2.0-only */

// Thermal Zone

External (\PPKG, MethodObj)

#define HAVE_THERMALZONE
Scope (\_TZ)
{
	ThermalZone (CRIT)
	{
		// Thermal zone polling frequency: 5 seconds
		Name (_TZP, 50)

		// Convert from Degrees C to 1/10 Kelvin for ACPI
		Method (CTOK, 1) {
			// 10th of Degrees C
			Local0 = Arg0 * 10

			// Convert to Kelvin
			Local0 += 2732

			Return (Local0)
		}

		// Threshold for OS to shutdown
		Method (_CRT, 0, Serialized)
		{
			Return (CTOK (\TCRT))
		}

		Method (_TMP, 0, Serialized)
		{
			// Get CPU Temperature from TIN9/PECI via EC
			Local0 = \_SB.PCI0.LPCB.EC0.TIN9

			// Check for sensor not calibrated
			If (Local0 == \_SB.PCI0.LPCB.EC0.TNCA) {
				Return (CTOK(0))
			}

			// Check for sensor not present
			If (Local0 == \_SB.PCI0.LPCB.EC0.TNPR) {
				Return (CTOK(0))
			}

			// Check for sensor not powered
			If (Local0 == \_SB.PCI0.LPCB.EC0.TNOP) {
				Return (CTOK(0))
			}

			// Check for sensor bad reading
			If (Local0 == \_SB.PCI0.LPCB.EC0.TBAD) {
				Return (CTOK(0))
			}

			// Adjust by offset to get Kelvin
			Local0 += \_SB.PCI0.LPCB.EC0.TOFS

			// Convert to 1/10 Kelvin
			Local0 *= 10
			Return (Local0)
		}
	}

	ThermalZone (THRM)
	{
		Name (_TC1, 0x02)
		Name (_TC2, 0x05)

		// Thermal zone polling frequency: 10 seconds
		Name (_TZP, 100)

		// Thermal sampling period for passive cooling: 2 seconds
		Name (_TSP, 20)

		// Convert from Degrees C to 1/10 Kelvin for ACPI
		Method (CTOK, 1) {
			// 10th of Degrees C
			Local0 = Arg0 * 10

			// Convert to Kelvin
			Local0 += 2732

			Return (Local0)
		}

		// Threshold for OS to shutdown
		Method (_CRT, 0, Serialized)
		{
			Return (CTOK (\TCRT))
		}

		// Threshold for passive cooling
		Method (_PSV, 0, Serialized)
		{
			Return (CTOK (\TPSV))
		}

		// Processors used for passive cooling
		Method (_PSL, 0, Serialized)
		{
			Return (\PPKG ())
		}

		Method (_TMP, 0, Serialized)
		{
			// Get Temperature from TIN# set in NVS
			Local0 = \_SB.PCI0.LPCB.EC0.TINS (TMPS)

			// Check for sensor not present
			If (Local0 == \_SB.PCI0.LPCB.EC0.TNPR) {
				Return (CTOK(0))
			}

			// Check for sensor not powered
			If (Local0 == \_SB.PCI0.LPCB.EC0.TNOP) {
				Return (CTOK(0))
			}

			// Check for sensor bad reading
			If (Local0 == \_SB.PCI0.LPCB.EC0.TBAD) {
				Return (CTOK(0))
			}

			// Adjust by offset to get Kelvin
			Local0 += \_SB.PCI0.LPCB.EC0.TOFS

			// Convert to 1/10 Kelvin
			Local0 *= 10
			Return (Local0)
		}

		/* CTDP Down */
		Method (_AC0) {
			If (\FLVL <= 0) {
				Return (CTOK (\F0OF))
			} Else {
				Return (CTOK (\F0ON))
			}
		}

		/* CTDP Nominal */
		Method (_AC1) {
			If (\FLVL <= 1) {
				Return (CTOK (\F1OF))
			} Else {
				Return (CTOK (\F1ON))
			}
		}

		Name (_AL0, Package () { TDP0 })
		Name (_AL1, Package () { TDP1 })

		PowerResource (TNP0, 0, 0)
		{
			Method (_STA) {
				If (\FLVL <= 0) {
					Return (1)
				} Else {
					Return (0)
				}
			}
			Method (_ON)  {
				\FLVL = 0
				\_SB.PCI0.MCHC.STND ()
				Notify (\_TZ.THRM, 0x81)
			}
			Method (_OFF) {
				\FLVL = 1
				\_SB.PCI0.MCHC.STDN ()
				Notify (\_TZ.THRM, 0x81)
			}
		}

		PowerResource (TNP1, 0, 0)
		{
			Method (_STA) {
				If (\FLVL <= 1) {
					Return (1)
				} Else {
					Return (0)
				}
			}
			Method (_ON)  {
				\FLVL = 1
				Notify (\_TZ.THRM, 0x81)
			}
			Method (_OFF) {
				\FLVL = 1
				Notify (\_TZ.THRM, 0x81)
			}
		}

		Device (TDP0)
		{
			Name (_HID, EISAID ("PNP0C0B"))
			Name (_UID, 0)
			Name (_PR0, Package () { TNP0 })
		}

		Device (TDP1)
		{
			Name (_HID, EISAID ("PNP0C0B"))
			Name (_UID, 1)
			Name (_PR0, Package () { TNP1 })
		}
	}
}