/* SPDX-License-Identifier: GPL-2.0-only */ /* * The mainboard must define a PNOT method to handle power * state notifications and Notify CPU device objects to * re-evaluate their _PPC and _CST tables. */ Device (EC0) { Name (_HID, EISAID ("PNP0C09")) Name (_UID, 1) Name (_GPE, EC_GPE) // GPE for Runtime SCI OperationRegion (ERAM, EmbeddedControl, 0x00, 0xff) Field (ERAM, ByteAcc, Lock, Preserve) { Offset (0x80), BTEX, 1, // Battery Exists , 1, ACEX, 1, // AC Exists , 5, Offset (0x83), LIDS, 1, // Lid Switch State , 7, BTST, 8, // Battery State Offset (0xA2), BTRA, 16, // Battery Remaining Capacity BTPR, 16, // Battery Present Rate BTVO, 16, // Battery Present Voltage Offset (0xB0), BTDA, 16, // Battery Design Capacity BTDF, 16, // Battery Last Full Charge Capacity BTDV, 16, // Battery Design Voltage BTDL, 16, // Battery Design Low Offset (0xC0), CPUT, 8, // CPU Temperature Offset (0xCA), FSL0, 1, // Fan Speed Level 0 FSL1, 1, // Fan Speed Level 1 FSL2, 1, // Fan Speed Level 2 FSL3, 1, // Fan Speed Level 3 FSL4, 1, // Fan Speed Level 4 , 2, FCOS, 1, // Fan Speed OS Control } Method (_CRS, 0, Serialized) { Name (ECMD, ResourceTemplate() { IO (Decode16, 0x62, 0x62, 0, 1) IO (Decode16, 0x66, 0x66, 0, 1) }) Return (ECMD) } Method (_REG, 2, NotSerialized) { // Initialize AC power state \PWRS = ACEX // Initialize LID switch state \LIDS = LIDS // Enable OS control of fan speed FCOS = 1 // Force a read of CPU temperature Local0 = CPUT /* So that we don't get a warning that Local0 is unused. */ Local0++ } PowerResource (FNP0, 0, 0) { Method (_STA) { If (\FLVL <= 0) { Return (1) } Else { Return (Zero) } } Method (_ON) { If (FCOS) { FSL0 = 1 \FLVL = 0 Notify (\_TZ.THRM, 0x81) } } Method (_OFF) { If (FCOS) { FSL0 = Zero \FLVL = 1 Notify (\_TZ.THRM, 0x81) } } } PowerResource (FNP1, 0, 0) { Method (_STA) { If (\FLVL <= 1) { Return (1) } Else { Return (Zero) } } Method (_ON) { If (FCOS) { FSL1 = 1 \FLVL = 1 Notify (\_TZ.THRM, 0x81) } } Method (_OFF) { If (FCOS) { FSL1 = Zero \FLVL = 2 Notify (\_TZ.THRM, 0x81) } } } PowerResource (FNP2, 0, 0) { Method (_STA) { If (\FLVL <= 2) { Return (1) } Else { Return (Zero) } } Method (_ON) { If (FCOS) { FSL2 = 1 \FLVL = 2 Notify (\_TZ.THRM, 0x81) } } Method (_OFF) { If (FCOS) { FSL2 = Zero \FLVL = 3 Notify (\_TZ.THRM, 0x81) } } } PowerResource (FNP3, 0, 0) { Method (_STA) { If (\FLVL <= 3) { Return (1) } Else { Return (Zero) } } Method (_ON) { If (FCOS) { FSL3 = 1 \FLVL = 3 Notify (\_TZ.THRM, 0x81) } } Method (_OFF) { If (FCOS) { FSL3 = Zero \FLVL = 4 Notify (\_TZ.THRM, 0x81) } } } PowerResource (FNP4, 0, 0) { Method (_STA) { If (\FLVL <= 4) { Return (1) } Else { Return (Zero) } } Method (_ON) { If (FCOS) { FSL4 = 1 \FLVL = 4 Notify (\_TZ.THRM, 0x81) } } Method (_OFF) { If (FCOS) { FSL4 = Zero \FLVL = 5 Notify (\_TZ.THRM, 0x81) } } } Device (FAN0) { Name (_HID, EISAID ("PNP0C0B")) Name (_UID, 0) Name (_PR0, Package () { FNP0 }) } Device (FAN1) { Name (_HID, EISAID ("PNP0C0B")) Name (_UID, 1) Name (_PR0, Package () { FNP1 }) } Device (FAN2) { Name (_HID, EISAID ("PNP0C0B")) Name (_UID, 2) Name (_PR0, Package () { FNP2 }) } Device (FAN3) { Name (_HID, EISAID ("PNP0C0B")) Name (_UID, 3) Name (_PR0, Package () { FNP3 }) } Device (FAN4) { Name (_HID, EISAID ("PNP0C0B")) Name (_UID, 4) Name (_PR0, Package () { FNP4 }) } // AC Power Connected Method (_Q51, 0, NotSerialized) { \PWRS = 1 Notify (AC, 0x80) \PNOT () } // AC Power Removed Method (_Q52, 0, NotSerialized) { \PWRS = Zero Notify (AC, 0x80) \PNOT () } // Battery State Change Method (_Q53, 0, NotSerialized) { Notify (BAT0, 0x80) Notify (BAT0, 0x81) } // Battery State Change Method (_Q54, 0, NotSerialized) { Notify (BAT0, 0x80) Notify (BAT0, 0x81) } // Power State Change Method (_Q55, 0, NotSerialized) { \PNOT () } // Lid Switch Event Method (_Q5E, 0, NotSerialized) { \LIDS = LIDS Notify (\_SB.LID0, 0x80) } // Lid Switch Event Method (_Q5F, 0, NotSerialized) { \LIDS = LIDS Notify (\_SB.LID0, 0x80) } #include "ac.asl" #include "battery.asl" }